Pular para o conteúdo
Merck
Todas as fotos(1)

Documentos Principais

G1006564

AOAC Method 2012.13: GC Analysis of Fatty Acids in Powdered Infant Formula on SP®-2560

suitable for GC

Faça loginpara ver os preços organizacionais e de contrato


About This Item

técnica(s)

gas chromatography (GC): suitable

parâmetros de teste

sample/matrix: weigh 168 mg powdered infant formula (approximately 50 mg of fat) into a 25 mL centrifuge tube; add 2 mL of water and mix to dissolve; (let sit for 15 minutes at room temperature; add 5 mL of internal standard (C11:0 FAME + C13:0 TAG, each at 2 mg/mL in methyl tert butyl ether))
extraction: 5 mL of 5% (w/v) methanolic sodium methoxide solution; close tube and vortex for 10 seconds; after 180 seconds (time starts when sodium methoxide is added) add 2 mL of hexane; (after 210 seconds add 10 ml of neutralization solution (10% disodium hydrogen citrate/15% sodium chloride in water); gently shake using vortex mixer; centrifuge mixture at 1750 rpm for 5 minutes)
eluate post-treatment: transfer 200 μL of supernatant into 10 mL flask and dilute to mark with hexane
column: SP-2560, 100 m x 0.25 mm I.D., 0.20 μm (24056)
oven: 60 °C (1 min), 15 °C/min to 165 °C (1 min), 2 °C/min to 225 °C (20 min)
inj. temp.: 250 °C
detector: FID, 250 °C
carrier gas: helium, 0.8 mL/min
injection: 1μL, 10:1 split
liner: 4 mm I.D., split/splitless type, wool packed single taper FocusLiner design

aplicação(ões)

food and beverages

Nota de análise

The nutritional content of infant formula is extremely critical, and thus is one of the most regulated food products worldwide. Most commercial infant formulas are derived from cow′s milk, and are formulated to mimic human breast milk. They offer the advantage of being nutritionally balanced and easy for most babies to digest. All infant formulas, whether cow′s milk-based or from another source, are subject to specific regulatory nutritional content requirements. AOAC Method 2012.13 using a 100 m SP-2560 is able to provide identification of fatty acids, as well as determination of total fatty acid content and breakdown by class.

Informações legais

FocusLiner is a trademark of SGE Analytical Science Pty Ltd.
SP is a registered trademark of Sigma-Aldrich Co. LLC

Analito

Descrição

    C8:0
    C10:0
    C11:0 (I.S.)
    C12:0
    C13:0 (I.S.)
    C14:0
    C14:1n5
    C15:0
    C16:0
    C16:1n7
    C17:0
    C17:1n7
    C18:0
    C18:1 trans
    C18:1 cis
    C18:2n6
    C18:2n7
    C18:3n6
    C18:3n3
    C20:0
    C20:1n9
    C20:2n6
    C20:3n3
    C20:4n6
    C22:0
    C22:1n9
    C22:6n3 (DHA)
    C24:0
    Ver tudo (28)

Padrão

Nº do produto
Descrição
Preços

coluna analítica


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Se precisar de ajuda, entre em contato Atendimento ao cliente

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.