Manual Bubble Flowmeter (Standard Version)

flow meter volume 10 mL, pkg of 1 ea

Sinônimo(s):

FLOWMETER 10CC EA

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
41112500

embalagem

pkg of 1 ea

técnica(s)

gas chromatography (GC): suitable

volume do medidor de vazão

10 mL

Procurando produtos similares? Visita Guia de comparação de produtos

Descrição geral

Bubble flowmeter is a simple and precise way to measure flow rates of gases. It is the most common device for measuring a volumetric flow rate. This unit has a buret of appropriate volume fitted with rubber bulb at the bottom and a side arm. Air is passed into the buret and the bulb filled with soap solution is squeezed. This causes a soap bubble to enter the buret. The time taken for the bubble to travel in considered as known volume, used to calculate the flow rate.
The most basic configuration of a bubble flowmeter is a calibrated tube, a stopwatch, and a good eye. The bubble is timed as it moves up the calibrated tube between two markings. Flow tubes are graduated as follows:
  • 10 mL tube in 1 mL increments
  • 25 mL tube in 5 mL increments
  • 50 mL tube in 10 mL increments
  • 100 mL tube in 20 mL increments
Includes glass flow tube with two magnetic clamps, a short piece of Tygon tubing and a squeeze bulb. Stand not included.

Aplicação

Bubble flowmeter may be used to manually control the flow at the system outlet during analysis of perfluorobutane (PFB) in the exhaled rat air using respiration-metabolism chamber system and a GC-MS method. Bubble flowmeters can be used to check splitter or detector flow or to calibrate personal pumps for accurate air sampling.

Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Se precisar de ajuda, entre em contato Atendimento ao cliente

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

The accuracy of the bubble meter method for gas flow measurements
Levy, A
Journal of Scientific Instruments, 41, 449-453 (1964)
Arthur C. Stern
Air Pollution: Measuring, Monitoring, and Surveillance of Air Pollution, 160-160 (1976)
Steinar Uran et al.
Journal of pharmaceutical and biomedical analysis, 39(3-4), 746-751 (2005-06-21)
Sonazoid is a new contrast agent for ultrasound imaging comprising an aqueous suspension of lipid-stabilised perfluorobutane (PFB) gas microbubbles. A respiration-metabolism chamber system was developed to collect exhaled air following intravenous administration of Sonazoid to rats. Analysis of PFB in

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica