Pular para o conteúdo
Merck
Todas as fotos(1)

Documentos

KN50A05FF1

Millipore

Opticap® XL5 Polygard® CN

inlet connection diam. 3/4 in., pore size 5.0 μm, cartridge nominal length 5 in. (12.5 cm)

Sinônimo(s):

Opticap XL5 Polygard-CN 5.0 μm 3/4 in. TC/TC

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
23151806
eCl@ss:
32031690

Materiais

polypropylene
polypropylene housing
polypropylene support
polypropylene vent cap
silicone seal

Nível de qualidade

conformidade reg.

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

fabricante/nome comercial

Opticap®

Parâmetros

1.0 bar max. inlet pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
4.8 bar max. differential pressure (70 psid) at 20 °C
5.5 bar max. inlet pressure (80 psi) at 25 °C
80 psig max. inlet pressure

Comprimento

21.6 cm (8.5 in.)

comprimento nominal do cartucho

5 in. (12.5 cm)

Diâmetro

10.7 cm (4.2 in.)

área de filtração

0.18 m2

diâm. conexão de entrada

3/4 in.

L entrada para a saída

21.6 cm (8.5 in.)

diam. conexão de saída

3/4 in.

Impurezas

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

extraíveis gravimétricos

≤25 mg/capsule

matriz

Polygard®-CN

tamanho de poro

5.0 μm nominal pore size
5.0 μm pore size

entrada

sample type liquid

conector

inlet sanitary flange
19 mm (3/4 in.) inlet/outlet sanitary flange
outlet sanitary flange

Descrição geral

Device Configuration: Capsule

Características e benefícios

Format: Single Layer

Embalagem

Double Easy-Open bag

Outras notas

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Nota de preparo

Sterilization Method
3 autoclave cycles of 30 min @ 126 °C; not in-line steam sterilizable

Nota de análise

Gravimetric Extractables: after 24 hours in water at controlled room temperature
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L

Informações legais

OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany
POLYGARD is a registered trademark of Merck KGaA, Darmstadt, Germany

Exoneração de responsabilidade

EMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.

Certificados de análise (COA)

Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica