KEGBG003FF3
Millipore Express® SPG 0.2 µm, Opticap® XL Capsule
Opticap® XL 300, inlet connection diam. 3/4 in., pore size 0.2 μm
Sinônimo(s):
Gamma Phobic Opticap® XL 300 Express SPG 0.2 sanitary flange
About This Item
Produtos recomendados
Materiais
polyethersulfone membrane
polyethylene support
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap
polysulfone
silicone seal
Nível de qualidade
esterilidade
irradiated
non-sterile
Compatibilidade de esterilização
gamma compatible
linha de produto
Opticap® XL 300
Características
hydrophobic
fabricante/nome comercial
Opticap®
Parâmetros
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
25 °C max. inlet temp.
4.1 bar max. inlet pressure (60 psi) at 23 °C
4.2 bar max. differential pressure (60 psid) at 25 °C (Forward)
60 psi max. differential pressure (4.1 bar) (continuous)
60 psig max. inlet pressure
técnica(s)
gas filtration: suitable
Comprimento
11.9 cm (4.7 in.)
Diâmetro
5.6 cm (2.2 in.)
área de filtração
0.048 m2
diâm. conexão de entrada
3/4 in.
L entrada para a saída
11.9 cm (4.7 in.)
diam. conexão de saída
3/4 in.
Impurezas
≤0.25 EU/mL (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
extraíveis gravimétricos
≤3 mg
Matriz
Millipore Express® SPG
tamanho de poro
0.2 μm pore size
ponto de bolha
≥1210 mbar (17.5 psig), air with 70/30% IPA/water at 23 °C
conector
1/4 in. drain/vent hose barb (with double O-ring seal)
inlet sanitary flange
outlet sanitary flange
(19 mm (3/4 in.) Sanitary Flange Inlet and Outlet)
Condições de expedição
ambient
Procurando produtos similares? Visita Guia de comparação de produtos
Descrição geral
Embalagem
Outras notas
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Nota de preparo
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Nota de análise
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After gamma irradiation and three autoclave cycles, the TOC was measured to be equal to or less than 3367 µg/device.
Informações legais
Exoneração de responsabilidade
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Global Trade Item Number
SKU | GTIN |
---|---|
KEGBG003FF3 | 4053252970405 |
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica