HCMP1MAG-19K
MILLIPLEX® Human Complement Panel 1 - Immunology Multiplex Assay
The Human Complement Panel 1 Bead-Based Multiplex Assay kit, using the Luminex xMAP technology, enables the simultaneous analysis of complement proteins and factors in human serum, plasma and cell culture samples.
Sinônimo(s):
Human complement multiplex kit, Luminex® human complement immunoassay, Millipore human complement panel
About This Item
Produtos recomendados
Nível de qualidade
reatividade de espécies
human
fabricante/nome comercial
Milliplex®
assay range
accuracy: 96%
(Mannose-Binding Lectin (MBL))
sensitivity: 0.0051 ng/mL
(Complement C5a)
sensitivity: 0.026 ng/mL
(Adipsin (Complement Factor D))
sensitivity: 0.040 ng/mL
(Mannose-Binding Lectin (MBL))
sensitivity: 0.22 ng/mL
(Complement Factor I)
sensitivity: 0.31 ng/mL
(Complement C2)
sensitivity: 0.36 ng/mL
(Complement C4b)
sensitivity: 1.040 ng/mL
(Complement C5)
standard curve range: 0.069-50 ng/mL
(Adipson/ Complement Factor D)
standard curve range: 0.07-50 ng/mL
(Complement C2)
standard curve range: 0.137-100 ng/mL
(Mannose-Binding Lectin (MBL))
standard curve range: 0.69-500 ng/mL
(Complement Factor I)
standard curve range: 1.37-1,000 ng/mL
(Complement C4b)
standard curve range: 2.74-2,000 ng/mL
(Complement C5)
standard curve range: 4.12-30,000 pg/mL
(Complement C5a)
técnica(s)
multiplexing: suitable
método de detecção
fluorometric (Luminex xMAP)
Condições de expedição
2-8°C
Categorias relacionadas
Descrição geral
MILLIPLEX® Complement Panel 1 Bead Panel is an 7-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum, plasma or culture supernatant samples: C2, C4B, C5, C5a, Adipsin/Complement Factor D, MBL and Complement Factor I.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Immune Response
Especificidade
Cross-reactivity between the antibodies and any of the other analytes in this panel is non-detectable or negligible.
Aplicação
- Analytes: C2, C4b, C5, C5a, Adipsin/Factor D, Mannose-Binding Lectin (MBL), and Factor I
- Recommended Sample type: Serum, plasma, and tissue/cell culture supernatant
- Recommended Sample dilution: 1:200 diluted plasma or serum. Tissue culture supernatant may require a dilution with an appropriate control medium prior to assay
- Assay Run Time: Overnight or two-hour primary incubation
- Research Category: Inflammation & Immunology
- Research Subcategory: Inflammation
- Note: To avoid complement activation in samples, which will affect the results, samples should be thawed as rapidly as possible, put on ice and assayed immediately
Características e benefícios
Embalagem
Armazenamento e estabilidade
Informações legais
Exoneração de responsabilidade
Palavra indicadora
Danger
Frases de perigo
Declarações de precaução
Classificações de perigo
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
Órgãos-alvo
Respiratory Tract
Código de classe de armazenamento
10 - Combustible liquids
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Conteúdo relacionado
Immunology multiplex assays, like MILLIPLEX® assays, allow researchers to investigate more immune biomarkers simultaneously, saving time and resources. This is especially critical to immunology research, where numerous analytes play a role in different pathways.
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica