SRE0103
MS β-Glucuronidase
Prebuffered, automation-ready hydrolysis mix
Synonyme(s) :
GUS, MS beta-Glu, beta-Gluc, bgluc
Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme
About This Item
Produits recommandés
Niveau de qualité
Forme
ready-to-use solution
Conditions d'expédition
ambient
Température de stockage
2-8°C
Catégories apparentées
Description générale
- Protocol: MS β-Glucuronidase Quick Start Guide
- MS β-Glucuronidase is a stable recombinant β-Glucuronidase mix for robust urine drug testing. Hydrolysis is completed at room-temperature or in your autosampler in a single-step . The stability and low-temperature compatibility allows an analyst to use MS β-Gluc as a bench-top reagent. Reliable hydrolysis over days on the bench means less hands-on time, less frequent reagent prep, and more automation. It has been verified against a broad spectrum of conjugated analytes, including “hard to cleave” glucuronides, particularly opiates and opioids. MS β-Gluc eliminates sample preparation bottlenecks while enabling fully automated hydrolysis and reproducible analytical results.
Application
- Urine sample preparation in Forensic and Clinical toxicology laboratories
- Enzymatic hydrolysis of drug glucuronide conjugates for urine drug testing by LC/MS
- Forensic drug testing, workplace and prescription drug monitoring, antidoping, SAMHSA
- Compatible with wide range of glucuronide drug conjugates, including but not limited to opioids, opiates, benzodiazepines and cannabinoids and hormones.
Caractéristiques et avantages
- Opened bottle retains 97% activity at 25°C after 2 months.
- Stable on the bench in MasterMix (with methanol): Retains 99% activity for a week.
- Pre-buffered for use with human urine with volatile buffer ammonium acetate for LC-MS.
- Single-step hydrolysis at room-temperature or within autosampler (20-40°C).
- Verified with real human urine samples, not synthetic.
- “Walk-away” workflow.
- Automation compatibility (oven and centrifuge not required).
- Purified recombinant enzyme
Notes préparatoires
For Opiates, Opioids and Broad-spectrum drug hydrolysis use 80 to 160 μL of MS ß-Glucuronidase per reaction for a 200 μL reaction in urine, so 6-12 samples can be hydrolyzed per mL of MS beta-Gluc depending on reaction temperature.
Dilute-and-shoot workflows: add MS β-glucuronidase formula and internal standards in methanol to urine and immediately transfer to autosampler at 40°C. After 16min switch temperature to 4°C. Hydrolyzed samples are ready for injection.
Workflows with extraction or filtration step: add MS β-glucuronidase formula and internal standards in methanol to urine. Incubate 30 min at room-temperature. Proceed with extraction or filtration.
Dilute-and-shoot workflows: add MS β-glucuronidase formula and internal standards in methanol to urine and immediately transfer to autosampler at 40°C. After 16min switch temperature to 4°C. Hydrolyzed samples are ready for injection.
Workflows with extraction or filtration step: add MS β-glucuronidase formula and internal standards in methanol to urine. Incubate 30 min at room-temperature. Proceed with extraction or filtration.
Stockage et stabilité
- Long term Storage: 24 months at 2 - 8 °C.
- Ambient for 2 months.
- Ambient for 1 week in Master Mix (11% methanol).
Code de la classe de stockage
12 - Non Combustible Liquids
Classe de danger pour l'eau (WGK)
WGK 1
Point d'éclair (°F)
Not applicable
Point d'éclair (°C)
Not applicable
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique