Accéder au contenu
Merck
Toutes les photos(1)

Key Documents

GE28-9782-42

HiScreen Butyl High Performance

Cytiva 28-9782-42

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
13111000
Nomenclature NACRES :
NA.56

ligand

butyl

Conditionnement

pkg of 4.7 mL

Fabricant/nom de marque

Cytiva 28-9782-42

Paramètres

44 psi

Taille du lit

7.7 mm × 100 mm

Volume du lit

4.7 mL

D.I. de la colonne

7.7 mm

Matrice

cross-linked agarose

Taille des particules

24-44 μm

Taille moy. des particules

34 μm

cleaning

2-14

working range

3-13

Adéquation

suitable for bioprocess medium

Description générale

HiScreen Butyl HP columns are prepacked with Butyl Sepharose High Performance hydrophobic interaction chromatography (HIC) media. The columns are an excellent choice for method optimization and parameter screening.

Application

The small column volume of 4.7 mL and bed height of 10 cm make HiScreen columns excellent tools for method optimization, parameter screening, robustness testing, and convenient scale-up. Process fluid velocities can be applied, since the 10 cm bed height gives enough residence time and the results can then serve as basis for linear process scale-up.

If necessary, two columns can easily be connected in series to give a bed height of 20 cm.

Media prepacked in HiScreen HIC columns are also available in other formats and as bulk packs, which makes it possible to use the same media for development work, pilot studies, and routine production.

Caractéristiques et avantages

  • Phenyl Sepharose High Performance is an aromatic HIC medium, designed for intermediate and polishing step purification steps when high resolution has priority.
  • Prepacked, ready-to-use columns for convenient process development optimization.
  • 10 cm bed height of HiScreen columns is designed to allow method optimization and parameter screening.
  • Easily connected in series to achieve 20 cm bed height.
  • Small bed volume gives fast results and minimal sample/buffer consumption.
  • Reproducible results, scalable to BioProcess columns packed with the same media using the same linear fluid velocity.

Stockage et stabilité

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Store at 4 to 30 °C (20% Ethanol or 0.01 M NaOH)
Store at 4 to 30 °C (20% Ethanol)

Remarque sur l'analyse

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Informations légales

HiScreen is a trademark of Cytiva
Sepharose is a trademark of Cytiva

Produit(s) apparenté(s)

Pictogrammes

Flame

Mention d'avertissement

Warning

Mentions de danger

Code de la classe de stockage

3 - Flammable liquids


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique