GE17-0947-20
SOURCE™ 15Q
Cytiva 17-0947-20, pack of 10 mL
About This Item
Produits recommandés
ligand
quaternary ammonium
Description
Ion Exchanger Type (value)
Conditionnement
pack of 10 mL
Fabricant/nom de marque
Cytiva 17-0947-20
Matrice
polystyrene/divinylbenzene
Taille moy. des particules
15 μm
Taille des particules
15-15 μm
cleaning in place
1-14
working range
2-12
Adéquation
suitable for bioprocess medium (BioProcess medium. Process-scale quantities are available.)
suitable for bioprocess medium
Description générale
Application
With its very high resolution, SOURCE™ 15Q is suitable for polishing steps in in both research and industrial applications.
Through the combination of high quality assurance standards and a patented manufacturing process, particle structure is consistent both bead-to-bead and batch-to batch.
As member of the BioProcess media range, SOURCE™ 15Q meets industrial demands with security of supply and comprehensive technical and regulatory support.
Caractéristiques et avantages
- Mono-sized 15 um rigid beads gives Low back pressure and high flow rates allowing for high productivity
- Strong anion exchanger designed for high resolution polishing purification of Proteins, peptides and oligonucleotides
- High chemical stability allowing for wide range of working conditions with good resistance to cleaning conditions at high pH
Stockage et stabilité
Remarque sur l'analyse
Informations légales
Mention d'avertissement
Warning
Mentions de danger
Conseils de prudence
Code de la classe de stockage
3 - Flammable liquids
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Articles
This page shows Hydrophobic Interaction Chromatography (HIC) in a purification strategy.
Here the correct ways for Column, Media and Sample preparation for Hydrophobic Interaction Chomatography (HIC) with GE Healthcare media are detailed, including sample application, load volume and temperature
Protocoles
In this section the practical aspect of Reverse Phased Chromatography ( RPC) is discussed including media and column selection and eluent selection and preparation.
While ligands contribute significantly to the degree of hydrophobicity of a medium, the matrix can also influence the final selectivity. Chromatography media for hydrophobic interaction are made from porous matrices, chosen for their physical stability, their chemical resistance to stringent cleaning conditions and their low level of non-specific interaction.
This page discusses how to do a purification with SOURCE™ media from GE Healthcare
This page discusses various aspects of sample preparation for chromatographic purification.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique