GE17-0405-03
HiTrap® Protein G High Performance
Cytiva 17-0405-03, pack of 5 × 5 mL
Synonyme(s) :
HP columns, Protein G Sepharose column
About This Item
Produits recommandés
ligand
recombinant protein G lacking albumin-binding region
Conditionnement
pack of 5 × 5 mL
Fabricant/nom de marque
Cytiva 17-0405-03
Conditions de stockage
(20% Ehtanol)
(20% Ethanol)
Paramètres
42 psi
Taille du lit
16 mm × 25 mm
Volume du lit
5 mL
D.I. de la colonne
16 mm
Taille
Taille moy. des particules
34 μm
cleaning
2-9
Plage de travail
3-9
Capacité
>1 mg binding capacity (lgG/column)(The binding capacity has been determined with human polyclonal IgG.)
125 mg binding capacity(human IgG/column)
Température de stockage
2-8°C
Description générale
Caractéristiques et avantages
- High binding capacity of 25 mg IgG/mL medium and fast binding kinetics.
- 34 μm bead size for high performance, high-resolution purifications.
- Binds broad range of different species and subclasses of IgG.
- Simple and proven method giving reproducible results.
- Designed for use with syringe, peristalic pump, or chromatography system.
Stockage et stabilité
Remarque sur l'analyse
Informations légales
Produit(s) apparenté(s)
Mention d'avertissement
Warning
Mentions de danger
Conseils de prudence
Code de la classe de stockage
3 - Flammable liquids
Faites votre choix parmi les versions les plus récentes :
Certificats d'analyse (COA)
It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.
Si vous avez besoin d'assistance, veuillez contacter Service Clients
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Articles
This page shows how to perform a separation with the HiTrap Protein G HP from GE Healthcare, an Affinity Exclusion Chromatography product containing pre-packed Protein G.
This page shows how to perform sample desalting and buffer exchange for affinity chromatography of antibodies.
This page shows how to solve practical problems that may occur when running an affinity chromatography column.
Protocoles
This page shows how to perform a two-step purification of mouse monoclonal IgG1 using HiTrap Protein G HP from GE Healthcare for the capture step.
This page shows general instructions for affinity purification using HiTrap columns from GE Healthcare.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique