Accéder au contenu
Merck
Toutes les photos(2)

Key Documents

NHPPT1MG-46K

Millipore

MILLIPLEX® Non-Human Primate Pituitary Magnetic Bead Panel 1 - Endocrine Multiplex Assay

The analytes available for this multiplex kit are: ACTH, AGRP, CNTF, FSH, GH, LH, TSH.

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12161503
eCl@ss :
32161000
Nomenclature NACRES :
NA.84

Niveau de qualité

Espèces réactives

nonhuman primates

Fabricant/nom de marque

Milliplex®

assay range

accuracy: 112%
(ACTH)

accuracy: 113%
(TSH)

accuracy: 71%
(CNTF)

accuracy: 98%
(FSH)

sensitivity: 0.005 μIU/mL
(TSH)

sensitivity: 0.012 mIU/mL
(FSH)

sensitivity: 0.013 mIU/mL
(LH)

sensitivity: 0.79 pg/mL
(ACTH)

sensitivity: 0.80 pg/mL
(AGRP)

sensitivity: 2.03 pg/mL
(GH)

sensitivity: 37.42 pg/mL
(CNTF)

standard curve range: 0.024-100 μIU/mL
(TSH)

standard curve range: 0.024-100 mIU/mL
(FSH)

standard curve range: 0.049-200 mIU/mL
(LH)

standard curve range: 12-50,000 pg/mL
(GH)

standard curve range: 122-500,000 pg/mL
(CNTF)

standard curve range: 2.4-10,000 pg/mL
(AGRP)

standard curve range: 3.0-12,500 pg/mL
(ACTH)

Technique(s)

multiplexing: suitable

Méthode de détection

fluorometric (Luminex xMAP)

Conditions d'expédition

wet ice

Description générale

Called the “master gland” because it controls many other endocrine glands, the pituitary secretes several key hormones that play important roles in the regulation of metabolism, growth, and reproduction. Pituitary hormones are responsible for the stimulation of the adrenal gland (ACTH), thyroid gland (TSH), ovaries and testes (FSH, LH), as well as blood pressure and the amount of water excreted by the kidneys. Through its connection with the pituitary, the hypothalamus modulates endocrine function by detecting hormone levels.

MILLIPLEX® Non-Human Primate Pituitary Panel 1 is a 7-plex kit to be used for the simultaneous quantification of any or all of the following analytes in non-human primate serum, plasma, and tissue culture samples: ACTH, AGRP, CNTF, FSH, GH, LH, and TSH. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.

The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.

Panel Type: Endocrine

Spécificité

Cross Reactivty
The antibody pairs in the panel are specific only to the desired analyte and exhibit no or negligible (<2%) cross-reactivity with other analytes in the panel.

Application

  • Analytes: ACTH, Agouti-Related Protein (AGRP), CNTF, FSH, GH, LH, TSH
  • Recommended Sample Type: Non-human primate serum, plasma, cell/tissue supernatants
  • Recommended Sample Dilution: 25 μL per well of undiluted serum or plasma; cell/tissue culture samples may require dilution in an appropriate control medium
  • Assay Run Time: Overnight (16-18 hours) at 2-8°C
  • Research Category: Endocrine
  • Research Subcategory: Metabolism

Caractéristiques et avantages

Design your multiplex kit by choosing available analytes within this panel.

Stockage et stabilité

Recommended storage for kit components is 2 - 8°C.

Informations légales

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Clause de non-responsabilité

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Pictogrammes

Skull and crossbonesEnvironment

Mention d'avertissement

Danger

Mentions de danger

Classification des risques

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Skin Sens. 1

Code de la classe de stockage

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Behavioural profiles in captive-bred cynomolgus macaques: towards monkey models of mental disorders?
Camus, SM; Blois-Heulin, C; Li, Q; Hausberger, M; Bezard, E
Testing null

Contenu apparenté

Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique