The analytes available for this multiplex kit are: AGT, Contactin-1, Fetuin A, Kallikrein-6, OPN, sSOD1, sSOD2
About This Item
Produits recommandés
Niveau de qualité
Espèces réactives
human
Fabricant/nom de marque
Milliplex®
assay range
accuracy: 69-92%
(Cerebrospinal fluid (CSF))
accuracy: 71-107%
(Serum)
standard curve range: 0.03-25 ng/mL
(SOD2)
standard curve range: 0.04-30 ng/mL
(Kallikrein-6)
standard curve range: 0.04-30 ng/mL
(SOD1)
standard curve range: 0.08-60 ng/mL
(Contactin-1)
standard curve range: 0.14-100 ng/mL
(Osteopontin (OPN))
standard curve range: 1.37-1,000 ng/mL
(AGT)
standard curve range: 4.12-3,000 ng/mL
(Fetuin A)
Technique(s)
multiplexing: suitable
Méthode de détection
fluorometric (Luminex xMAP)
Conditions d'expédition
wet ice
Description générale
NOTE: For serum and plasma samples Fetuin A requires a higher (1:4000) dilution and therefore must be assayed alone as a singleplex. For serum or plasma samples all analytes, except Fetuin A, require a 1:50 dilution and may be assayed together as a multiplex.
The MILLIPLEX® Human Neurological Disorders Bead Panel 3 (Cat. No. HND3MAG-39K) is to be used for the simultaneous quantification of the following 7 analytes in any combination in CSF, serum or plasma samples: Angiotensinogen (AGT), Contactin-1, Fetuin A, Kallikrein-6, Osteopontin (OPN), Soluble Superoxide Dismutase 1 (SOD1), Soluble Superoxide Dismutase 2 (SOD2).
NOTE: For serum and plasma samples Fetuin A requires a higher (1:4000) dilution and therefore must be assayed alone as a singleplex. For serum or plasma samples all analytes, except Fetuin A, require a 1:50 dilution and may be assayed together as a multiplex.
Panel Type: Neuroscience
Spécificité
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.
Application
- Analytes: Angiotensinogen (AGT), Contactin-1, Fetuin A, Kallikrein-6, Osteopontin (OPN), Soluble Superoxide Dismutase 1 (SOD1), Soluble Superoxide Dismutase 2 (SOD2)
- Recommended Sample type: CSF, serum, and plasma
- Recommended Sample dilution: 1:100 for CSF, 1:50 for serum and plasma for all analytes except Fetuin A, 1:4000 for serum and plasma for Fetuin A
- NOTE: Fetuin A cannot be assayed along with other analytes in serum/plasma samples. Fetuin A should be diluted 1:4000 in the kit Assay Buffer and analyzed as a singleplex for serum and plasma samples
- Assay Run Time: One day or Overnight
- Research Category: Neuroscience
Caractéristiques et avantages
Conditionnement
Stockage et stabilité
Autres remarques
Informations légales
Clause de non-responsabilité
Mention d'avertissement
Danger
Mentions de danger
Classification des risques
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
Organes cibles
Respiratory Tract
Code de la classe de stockage
10 - Combustible liquids
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Contenu apparenté
Neuroscience multiplex assays, such as MILLIPLEX® multiplex assays, enable simultaneous measurement of neuroscience-related biomarkers to gain a better picture of neurodegenerative diseases, neurological disorders, and neuropeptide/neurohormone signaling.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique