Accéder au contenu
Merck
Toutes les photos(3)

Documents

HIGFMAG-52K

Millipore

MILLIPLEX® Human IGF-I, II Magnetic Bead Panel - Endocrine Assay

The Human IGF Panel, using the Luminex xMAP technology, enables the simultaneous analysis of one or both IGF-I and IGF-II protein biomarkers in human serum, plasma and cell/tissue culture samples.

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12161503
eCl@ss :
32161000
Nomenclature NACRES :
NA.84

Niveau de qualité

Espèces réactives

human

Fabricant/nom de marque

Milliplex®

assay range

accuracy: 89%
(IGF-II)

sensitivity: 19 pg/mL
(MinDC+2SD; IGF-I)

sensitivity: 919 pg/mL
(MinDC+2SD; IGF-II)

standard curve range: 41-30,000 pg/mL
(IGF-I)

standard curve range: 892-650,000 pg/mL
(IGF-II)

inter-assay cv: <15%
intra-assay cv: <10%
(IGF-I)

inter-assay cv: <15%
intra-assay cv: <10%
(IGF-II)

Technique(s)

multiplexing: suitable

Numéro d'accès UniProt

Méthode de détection

fluorometric (Luminex xMAP)

Conditions d'expédition

wet ice

Informations sur le gène

human ... IGF1(3479)

Description générale

Insulin-like Growth Factors I and II are polypeptide, endocrine hormones similar in molecular structure to insulin. Both IGF-I and IGF-II are produced primarily by the liver and their bio-availabilities are regulated by the IGF binding proteins (IGFBPs).

MILLIPLEX® Human IGF-I, II Panel is a 2-plex kit to be used for the quantitative determination of IGF-I and/or IGF-II in human serum, plasma, tissue/cell extracts, or culture media samples. Reagents are included for the extraction of serum and plasma samples resulting in a 1:60 final dilution. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.

The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.

Panel Type: Endocrine

Spécificité

Cross Reactivty
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.
Cross-reactivity between the antibodies and any of the other analytes in this panel is non-detectable or negligible.

Application

  • Analytes: IGF-I, IGF-II
  • Recommended Sample Type: Human serum, plasma, cell/tissue culture supernatants or lysates
  • Recommended Sample Dilution: Use 25 μL per well of the final 1:60 extracted serum or plasma; Cell/tissue culture supernatants or lysates may require a dilution in appropriate control medium.
  • NOTE: Sample extraction, using the reagents included in the kit, is required for serum and plasma samples. The final dilution for extracted serum or plasma samples is 1:60.
  • Assay Run Time: Overnight (16-20 hours) at 2-8°C
  • Research Category: Metabolism
  • Research Subcategory: Metabolic Disorders

Caractéristiques et avantages

Design your multiplex kit by choosing available analytes within this panel.

Conditionnement

96 well plate
Everything you need in a single kit.

Stockage et stabilité

Recommended storage for kit components is 2 - 8°C.

Autres remarques

Please contact Technical Service for linearity of dilution.
Standard curve range: Refer to analysis sheet for exact standard concentracions.

Informations légales

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Clause de non-responsabilité

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Mention d'avertissement

Danger

Classification des risques

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Flam. Liq. 2 - Met. Corr. 1 - Skin Sens. 1

Code de la classe de stockage

3 - Flammable liquids


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Effects of maternal obstructive sleep apnoea on fetal growth: a prospective cohort study.
Fung, AM; Wilson, DL; Lappas, M; Howard, M; Barnes, M; O'Donoghue, F; Tong, S; Esdale et al.
Testing null
Kenneth Maleta et al.
The American journal of clinical nutrition, 113(2), 380-390 (2021-01-01)
Insulin-like growth factor I (IGF-I) is the most important hormonal promoter of linear growth in infants and young children. The objectives of this study were to compare plasma IGF-I concentration in a low- compared with a high-income country and characterize
Francesca D'Addio et al.
Nature communications, 13(1), 684-684 (2022-02-05)
Loss of pancreatic beta cells is a central feature of type 1 (T1D) and type 2 (T2D) diabetes, but a therapeutic strategy to preserve beta cell mass remains to be established. Here we show that the death receptor TMEM219 is

Contenu apparenté

Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique