Accéder au contenu
Merck
Toutes les photos(3)

Key Documents

HAIAB-10K

Millipore

MILLIPLEX® Human Autoimmune Autoantibody Panel

Milliplex®

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12161503
eCl@ss :
32161000
Nomenclature NACRES :
NA.47

Espèces réactives

human

Fabricant/nom de marque

Milliplex®

Technique(s)

multiplexing: suitable

Méthode de détection

fluorometric (Luminex xMAP)

Description générale

Autoantibody formation is principal to the pathogenesis of a variety of autoimmune diseases. Dysregulated apoptosis and the subsequent defective clearance of cellular debris leads to the exposure of autoantigens and the generation of autoantibodies. The presence of autoantibodies may indicate disease activity, prognosis, and clinical associations related to a variety of autoimmune diseases. These autoimmune diseases include, but are not limited to, Sjögren′s Syndrome, Systemic Lupus Erythematosus, Mixed Connective Tissue Disease, Systemic Sclerosis, CREST syndrome, Polymyositis/Dermatomyositis, Vasculitis, Anti-Phospholipid Syndrome, and various overlap syndromes of these diseases.

MILLIPLEX® Human Autoimmune Autoantibody Bead Panel is a 20-plex kit to be used for the simultaneous detection and profiling of any or all of the following analytes in serum and plasma samples: Anti-C1q, Anti-Centromere Protein A (CENP-A), Anti-Centromere Protein B (CENP-B), Anti-β 2-Glycoprotein, Anti-Jo-1, Anti-Ku, Anti-Mi-2, Anti-Myeloperoxidase, Anti-Proliferating cell nuclear antigen A (PCNA), Anti-Alanyl-tRNA synthetase (PL-12), Anti-PM/Scl-100, Anti-Proteinase 3, Anti-Ribosomal P, Anti-Ribonucleoprotein (RNP), Anti-RNP/Smith (RNP/Sm), Anti-Scl-70, Anti-Sm, Anti-Sjögren′s Syndrome-related antigen B/La (SSB/La), Anti-Anti-Sjögren′s Syndrome-related antigen A/Ro52 kDa (SSA/Ro52), Anti-Sjögren′s Syndrome-related antigen A/Ro60 kDa (SSA/Ro60). This panel includes 4 assay control beads as part of the base kit format. From our single to multiplex biomarker solutions, we partner with you to design, develop, analytically verify, and build the most comprehensive library available for autoantibody detection.

Panel Type: Immune Response

Spécificité

Cross Reactivty
Samples were incubated with no antigen, irrelevant antigen, or specific antigen. Incubation with a partcular antigen led to selective abrogation of the reactivity, while reactivity was unaffected by the irrelevant antigen.

Application

  • Analytes: β2-Glycoprotein, C1q, CENP-B (Centromere Protein B), CENP-A (Centromere Protein A), Jo-1, Ku, Mi-2, Myeloperoxidase (MPO), PCNA (Proliferating Cell Nuclear Antigen A), PL-12 (Alanyl-tRNA synthetase), PM/Scl 100, Proteinase 3, RNP (Ribonucleoprotein), RNP/Smith (RNP/Sm), Ribosomal P, Scl-70, Sm, SSB/La (Sjögren′s Syndrome-related antigen B/La), SSA/Ro60 (Sjögren′s Syndrome-related antigen A/Ro60 kDa), SSA/Ro52 (Sjögren′s Syndrome-related antigen A/Ro52 kDa)
  • This is a qualitative assay.
  • Four assay control beads are included in the base kit.
  • Recommended Sample type: serum and plasma.
  • Assay Run Time: Overnight
  • Research Category: Category Inflammation & Immunology
  • Research Subcategory: Autoimmune disease, Inflammation, Immune Response, Immune Disorders

Caractéristiques et avantages

Design your multiplex kit by choosing available analytes within this panel.

Conditionnement

96 well plate
Everything you need in a single kit.

Stockage et stabilité

Recommended storage for kit components is 2 - 8°C.

Informations légales

MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany

Clause de non-responsabilité

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Pictogrammes

Exclamation markEnvironment

Mention d'avertissement

Warning

Mentions de danger

Classification des risques

Aquatic Chronic 2 - Eye Irrit. 2 - Skin Sens. 1

Code de la classe de stockage

12 - Non Combustible Liquids

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Jieun Kwon et al.
The ocular surface, 18(1), 80-97 (2019-10-14)
To investigate the role of Anti-Citrullinated Protein autoantibodies (ACPAs) in the pathology of dry eye disease (DED) and the therapeutic potential of pooled human immune globulin-eye drops in these patients. We investigated the presence of citrullinated proteins and ACPAs in

Contenu apparenté

Multiplex analysis of autoantibodies, such as MILLIPLEX® multiplex assays, helps advance research by detecting multiple autoantibodies like cytokine autoantibodies, autoimmune autoantibodies, and cancer autoantibodies at once to give researchers a full picture of analyte concentrations.

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique