Accéder au contenu
Merck
Toutes les photos(1)

Key Documents

CN5074T06

Millipore

Filtre à cartouche Polygard® CN

nominal pore size 5.0 μm, cartridge nominal length × diam. 40 in. (1064.0-1072.0 mm) × 2.75 in. (70 mm)

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
23151806

Matériaux

polypropylene filter

Niveau de qualité

Caractéristiques

hydrophilic

Fabricant/nom de marque

Polygard

Paramètres

4.8 bar max. differential pressure (70 psid) at 20 °C

cartridge nominal length × diam.

40 in. (1064.0-1072.0 mm) × 2.75 in. (70 mm)

Impuretés

≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)

Extractibles par gravimétrie

≤10 mg

Dimension de pores

5.0 μm nominal pore size
5.0 μm pore size

Entrée

sample type liquid

Code de la cartouche

Code 7 (2-226; O-Ring with locking tab and spear)

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Polygard® CN products are nominally rated filters designed for particle removal applications in liquids and gases. The pleated structure of Polygard® CN filter media minimizes pressure differentials during the filtration process, and the all-polypropylene construction of these filters conveys low levels of extractables and broad chemical compatibility. Downstream filter performance is enhanced due to efficient particle and microorganism reduction.

Notes préparatoires

Sterilization: May be autoclaved for 10 cycles of 30 minutes at 126 °C or steam sterilized for 10 cycles for 30 minutes at 126 °C or hot water sanitized at 80 °C maximum for 30 minutes.

Remarque sur l'analyse

Gravimetric Extractables: After autoclaving and a 24-hour soak in ASTM® Type 1 reagent grade water at controlled room temperature, meets the USP Oxidizable Substances Test requirements of <50 mg.

Autres remarques

Directions for Use:

  • Organism Retention: Microorganism reduction
  • Mode of Action: Filtration (nominal)
  • Application: BioProcessing
  • Intended Use: Efficient particle and microorganism reduction
  • Instructions for Use: Please refer to the Polygard® and Clarigard® Cartridges user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

Informations légales

ASTM is a registered trademark of American Society for Testing and Materials
CLARIGARD is a registered trademark of Merck KGaA, Darmstadt, Germany
POLYGARD is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique