Accéder au contenu
Merck
Toutes les photos(1)

Key Documents

1.08879

Supelco

Zinc sulfate solution

c(ZnSO₄) = 0.1 mol/l, reag. Ph. Eur., reag. USP, ready-to-use volumetric solution for titration, Titriplex®

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12352302
Nomenclature NACRES :
NA.21

product name

Zinc sulfate solution, c(ZnSO4) = 0.1 mol/l, Titripur®, reag. Ph. Eur., reag. USP

Agence

reag. Ph. Eur.
reag. USP

Niveau de qualité

Gamme de produits

Titripur®

Forme

liquid

Qualité

Analyzed in our ISO 17025 accredited QC lab

Capacité de réaction

reaction type: Redox Reactions

Concentration

0.1 M

Technique(s)

titration: suitable

pH

4.8 (20 °C in H2O)

Densité

1.02 g/m3 at 20 °C

Température de stockage

15-25°C

Application


  • Quantitation of Mycophenolic Acid and Mycophenolic Acid Glucuronide in Serum or Plasma by LC-MS/MS.: This study demonstrates a liquid chromatography-mass spectrometry method using zinc sulfate solution as part of the sample preparation process. The method allows precise quantification of immunosuppressive drugs, enhancing therapeutic drug monitoring and clinical outcomes (Garg et al., 2023).

  • Targeted profiling of 24 sulfated and non-sulfated bile acids in urine using two-dimensional isotope dilution UHPLC-MS/MS.: Zinc sulfate solution is employed in this advanced analytical technique to enhance the detection and quantification of bile acids in urine. This application is crucial for diagnosing and monitoring liver and gastrointestinal diseases (Habler et al., 2022).

  • Rapid detection method of carbapenemase-producing Enterobacteriaceae by MALDI-TOF MS with imipenem/cilastatin (KB) disc and zinc sulfate solution.: This research utilizes zinc sulfate solution to improve the rapid detection of antibiotic resistance in bacteria via mass spectrometry, crucial for timely and effective treatment of infections (Oho et al., 2021).

Caractéristiques et avantages

Accreditation:
This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.

Conditionnement

SKU-pack size numbers ending with a "3" are SmartChemicals with an RFID tag on the label for seamless data transfer to the instrument, e.g. xxxxxx1003 or xxxxxxx 4003. More information on www.sigmaaldrich.com/SmartChemicals

Remarque sur l'analyse

Form liquid
Amount-of-substance concentration 0.0995 - 0.1005 mol/L
Measurement uncertainty ± 0.0003 mol/L
Traceability NIST SRM

The concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is determined with standardized titriplex-III solution (article number 1.08431). The titriplex-III solution is standardized and traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 682 Zinc) by means of volumetric standard Zinc (article number 1.02409), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.

Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.

Informations légales

Titripur is a registered trademark of Merck KGaA, Darmstadt, Germany

Produit(s) apparenté(s)

Réf. du produit
Description
Tarif

Pictogrammes

Exclamation mark

Mention d'avertissement

Warning

Mentions de danger

Classification des risques

Aquatic Chronic 3 - Eye Irrit. 2

Code de la classe de stockage

12 - Non Combustible Liquids

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique