Accéder au contenu
Merck
Toutes les photos(2)

Key Documents

GF22838799

Tantalum

wire reel, 10m, diameter 0.025mm, as drawn, 99.9%

Synonyme(s) :

Tantalum, TA005100, Ta

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule empirique (notation de Hill):
Ta
Numéro CAS:
Poids moléculaire :
180.95
Numéro MDL:
Code UNSPSC :
12141741
ID de substance PubChem :
Nomenclature NACRES :
NA.23

Pression de vapeur

<0.01 mmHg ( 537.2 °C)

Pureté

99.90%

Forme

wire

Température d'inflammation spontanée

572 °F

Fabricant/nom de marque

Goodfellow 228-387-99

Résistivité

13.5 μΩ-cm, 20°C

L × diam.

10 m × 0.025 mm

Point d'ébullition

5425 °C (lit.)

Pf

2996 °C (lit.)

Densité

16.69 g/cm3 (lit.)

Chaîne SMILES 

[Ta]

InChI

1S/Ta

Clé InChI

GUVRBAGPIYLISA-UHFFFAOYSA-N

Description générale

For updated SDS information please visit www.goodfellow.com.

Informations légales

Product of Goodfellow

Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Désolés, nous n'avons pas de COA pour ce produit disponible en ligne pour le moment.

Si vous avez besoin d'assistance, veuillez contacter Service Clients

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Robert Cohen
American journal of orthopedics (Belle Mead, N.J.), 31(4), 216-217 (2002-05-15)
Conventional materials used for orthopedic reconstruction implants limit the design of new and improved implants. Solid metal is rigid. Porous fixation surfaces have low volumetric porosity available for biologic ingrowth and low frictional characteristics for initial implant stability and have
J Black
Clinical materials, 16(3), 167-173 (1993-12-09)
A detailed literature search was carried out to define the current knowledge about the biological performance of tantalum. The pure metal appears, to a great degree, to be inert both in vivo and in vitro. Both the pure metal and
Jian Lu et al.
Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery, 26(2), 244-247 (2012-03-13)
To review the progress in the treatment of bone defect by porous tantalum implant. Recent literature was extensively reviewed and summarized, concerning the treatment method of bone defect by porous tantalum implant. By right of their unique properties, porous tantalum
Juncai Deng et al.
Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 28(2), 419-422 (2011-05-25)
This paper describes the biological characteristics of the metal tantalum (Ts) and the application status of tantalum in artificial joints, bone necrosis, spine, defects of bone and other aspects of bone. The early clinical application results of tantalum in bone
Giulio Maccauro et al.
Recent patents on biotechnology, 3(3), 157-165 (2009-06-24)
Tantalum is obtained from the minerals colombite, tantalite and euxenite. It is greyish silver, heavy and very hard. Tantalum does not react with body fluids and is used to make surgical equipment. Tantalum also does not irritate the body and

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique