BPCKHF09002S20
Hi-Flow™ Plus membrane 90
2mil backing, 20mm width, pack of 14 slit rolls
Synonym(s):
Hi-Flow, HF, lateral flow membrane, immunoassay membrane, nitrocellulose membrane
About This Item
Recommended Products
Quality Level
packaging
pack of 14 roll
manufacturer/tradename
Hi-Flow Plus
parameter
90 sec/4 cm capillary flow rate
backing thickness
2 mil (50 μm)
filter W × L
20 mm × 100 m
roll L
100 m (328 ft)
slit W
20 mm
Looking for similar products? Visit Product Comparison Guide
Related Categories
General description
Hi-Flow™ Plus 90 (HF090) is suitable for tests where speed is critical, the sample is plentiful, and sensitivity is not a concern. This Hi-Flow™ Plus 90 pack comprises 14 slit rolls of 2 mil backed nitrocellulose membrane with a nominal capillary flow time of 90 seconds/4 cm.
Application
- Hi-Flow™ Plus membrane is a critical raw material suitable for use in a broad range of Lateral Flow test applications, including Infectious Disease testing (COVID-19, HIV, Influenza, Malaria, STDs, etc.), as well as in women’s health, biomarker detection, drugs of abuse testing, drug development, environmental testing, agricultural applications, food safety, product quality testing, and animal health.
- It is suitable for use with all lateral flow test techniques including competitive, sandwich, and multiplex detection assays.
- It is optimized for use in both qualitative and quantitative test types and pairs well with lateral flow detector particles including colloidal gold nanoparticles, dyed/fluorescent microspheres, etc.
- It is suitable for use in lateral flow tests designed to detect analytes present in a broad range of sample matrices including, blood, saliva, urine, nasopharyngeal swabs, sweat, and others.
Features and Benefits
- Consistent flow and proprietary surface chemistry optimized for lateral flow applications.
- Robust manufacturing process.
- High Quality Level: MQ400.
- Trusted Partner and brand with decades of membrane manufacturing experience.High production capacity, high stock levels, multiple manufacturing lines.
- Convenient sample packs available in several formats.
- Manufacturing scale quantities available to purchase online with immediate shipping.
- We offer a complete solution; along with Hi-Flow™ Plus membranes we offer raw materials across the entire lateral flow workflow as well as assay development services: https://www.sigmaaldrich.com/US/en/services/ivd-development-manufacturing/lateral-flow-services.
- Consistent capillary flow time and membrane thickness.
- Superior surface morphology allows for consistent and even flow distribution of reagents across the membrane surface.
- Sharp, intense, and uniform test and control line formation.
- Excellent intra-lot and inter-lot consistency.
- Better assay sensitivity.
- Excellent reproducibility.
- Improved lateral flow test manufacturing yields.
- Quick delivery and lead time.
- No supply disruption.
- Excellent technical support.
Legal Information
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Articles
Explore design, materials, & manufacturing of lateral flow tests. Learn about reproducibility, optimization, & Hi-Flow™ Plus membranes for efficient scale-up.
Related Content
Discover critical membrane materials for your IVD lateral flow immunoassay development including Hi-Flow™ lateral flow membrane cards and SureWick® pad materials.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service