BMSMR9600TE
Benchmark SmartReader™ 96 Microplate Absorbance Reader with Incubation
AC/DC input 230 V, EuroPlug
Synonym(s):
Microplate reader, Absorbance reader, ELISA, 96 well plate, plate reader
Sign Into View Organizational & Contract Pricing
All Photos(1)
About This Item
Recommended Products
manufacturer/tradename
Benchmark Scientific MR9600-T-E
parameter
temp. range at Ambient +5 to 50 °C
Looking for similar products? Visit Product Comparison Guide
General description
The Accuris SmartReader 96, models MR9600 and MR9600T are welcome additions to any lab that is routinely measuring concentration or absorbance in 96 well plates. The 7 inch touch screen, intuitive software and graphical interface make these instruments easy to use as a standalone reader (a separate computer and additional software is not required).
Intuitive, 7 inch color touch screen control panel
Filter based system with wavelength range from 340 to 750nm
Operates as a stand alone system, with USB flash drive drive for data transfer
Absorbance range: 0.0 to 4.000 Abs
8 channel vertical optical path, with zero dispersion
Integrated, multispeed plate shaker
MR9600T features temperature controlled plate incubation
The SmartReader 96 comes complete with 4 popular filters: 405,450,492,630nm and twenty six additional filters are available separately to cover a full range from 340 to 750nm. The integrated filter wheel allows up to 8 filters to be loaded at once, and filters can be selected during programming
Use the touch screen, or connect a mouse for programming and operation. The menu interface allows the user to choose the wavelength filter, set shaking parameters, enter details of the plate layout, and also choose the details for the reading protocol and data calculations.
Model MR9600T offers precise temperature control for incubation of plates during processing. Temperature can be maintained at 5°C above ambient to 50°C.
Up to two filters can be used for 2 measurements of the sample plate, for calculated comparisons. Kinetic calculations can be performed by setting multiple readings.
The SmartReader 96 is a convenient stand alone reader, all software and the programing system is incorporated into the electronics. However, a convenient USB port on the side allows quick and easy saving of data files to a USB drive, and the universal .csv files can then be shared or transferred to a computer for storage or further processing. A data port can be used for connecting a computer or basic printer.
The plate layout interface allows for quick and intuitive set up of a plate’s well contents. The display shows a graphical representation of the 96 well plate, and the user can label each well as required for: “known standard”, “unknown sample”, “blank well”, “QC control well”, “negative control”, “positive control”, or “empty”. The interface allows highlighting and labeling multiple wells to save time.
Measurement data is available immediately on the screen after a reading, as well as interpretations, calculated analysis and curve fittings.
Intuitive, 7 inch color touch screen control panel
Filter based system with wavelength range from 340 to 750nm
Operates as a stand alone system, with USB flash drive drive for data transfer
Absorbance range: 0.0 to 4.000 Abs
8 channel vertical optical path, with zero dispersion
Integrated, multispeed plate shaker
MR9600T features temperature controlled plate incubation
The SmartReader 96 comes complete with 4 popular filters: 405,450,492,630nm and twenty six additional filters are available separately to cover a full range from 340 to 750nm. The integrated filter wheel allows up to 8 filters to be loaded at once, and filters can be selected during programming
Use the touch screen, or connect a mouse for programming and operation. The menu interface allows the user to choose the wavelength filter, set shaking parameters, enter details of the plate layout, and also choose the details for the reading protocol and data calculations.
Model MR9600T offers precise temperature control for incubation of plates during processing. Temperature can be maintained at 5°C above ambient to 50°C.
Up to two filters can be used for 2 measurements of the sample plate, for calculated comparisons. Kinetic calculations can be performed by setting multiple readings.
The SmartReader 96 is a convenient stand alone reader, all software and the programing system is incorporated into the electronics. However, a convenient USB port on the side allows quick and easy saving of data files to a USB drive, and the universal .csv files can then be shared or transferred to a computer for storage or further processing. A data port can be used for connecting a computer or basic printer.
The plate layout interface allows for quick and intuitive set up of a plate’s well contents. The display shows a graphical representation of the 96 well plate, and the user can label each well as required for: “known standard”, “unknown sample”, “blank well”, “QC control well”, “negative control”, “positive control”, or “empty”. The interface allows highlighting and labeling multiple wells to save time.
Measurement data is available immediately on the screen after a reading, as well as interpretations, calculated analysis and curve fittings.
Application
Reading microplates for ELISA assays
Legal Information
SmartReader is a trademark of Benchmark Scientific, Inc.
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service