Direkt zum Inhalt
Merck

96-0327

Lösungsmittel in Wasser, 20ppb

suitable for GC, application for SPME

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Methode(n)

gas chromatography (GC): suitable
solid phase microextraction (SPME): suitable

Testparameter

sample/matrix: solvents at 20 ppb in 4 mL water + 25% NaCl in 4 mL vial
SPME fiber: carboxen/PDMS, 75 μm (57318)
extraction: immersion, 10 min, rapid stirring
desorption process: 270 °C, 5 min
column: SPB-1 SULFUR, 30 m × 0.32 mm I.D., 4.0 μm film (24158)
oven: 50°C (2 min) to 150°C at 10°C/min
inj. temp.: splitless (closed 2 min), 260°C, 0.75 mm I.D. liner
detector: FID
carrier gas: helium, 30 cm/sec

Eignung

application for SPME

Anwendung(en)

chemicals and industrial polymers
environmental
forensics and toxicology

Rechtliche Hinweise

SPB is a registered trademark of Merck KGaA, Darmstadt, Germany

Analyt

Beschreibung

    Ethyl acetate
    3-Methyl-2-butanone
    Methanol

Analytische Säule

Produkt-Nr.
Beschreibung
Preisangaben

Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Leider sind derzeit keine COAs für dieses Produkt online verfügbar.

Wenn Sie Hilfe benötigen, wenden Sie sich bitte an Kundensupport

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.