About This Item

CAS-Nummer:
MDL-Nummer:
UNSPSC-Code:
77101502
NACRES:
NA.24

Qualität

certified reference material
TraceCERT®

Qualitätsniveau

Agentur

EPA TO-8
NIOSH 2001
OSHA 32

Produktlinie

TraceCERT®

Analysenzertifikat (CofA)

current certificate can be downloaded

Leistungsmerkmale

standard type calibration

Verpackung

ampule of 1 mL

Konzentration

5000 μg/mL in methanol

Methode(n)

HPLC: suitable
gas chromatography (GC): suitable

Anwendung(en)

agriculture
environmental

Format

single component solution

Lagertemp.

2-8°C

SMILES String

Oc1ccc(cc1)C

InChI

1S/C7H8O/c1-6-2-4-7(8)5-3-6/h2-5,8H,1H3

InChIKey

IWDCLRJOBJJRNH-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Anwendung

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Sonstige Hinweise

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Rechtliche Hinweise

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

Signalwort

Danger

Gefahreneinstufungen

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

Zielorgane

Eyes

Lagerklassenschlüssel

3 - Flammable liquids

WGK

WGK 2

Flammpunkt (°F)

49.5 °F - closed cup

Flammpunkt (°C)

9.7 °C - closed cup

Persönliche Schutzausrüstung

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Zulassungslistungen

Zulassungslistungen werden hauptsächlich für chemische Produkte erstellt. Für nicht-chemische Produkte können hier nur begrenzte Angaben gemacht werden. Kein Eintrag bedeutet, dass keine der Komponenten gelistet ist. Es liegt in der Verantwortung des Benutzers, die sichere und legale Verwendung des Produkts zu gewährleisten.

EU REACH Annex XVII (Restriction List)

CAS No.

Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumente section.

Wenn Sie Hilfe benötigen, wenden Sie sich bitte an Kundensupport

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

F Basheer et al.
Environmental technology, 33(16-18), 1847-1856 (2012-12-18)
The present study was aimed at the development of aerobic granules in a sequencing batch reactor for the biodegradation of m-cresol. The reactor was started with 100 mg L(-1)of m-cresol. Aerobic granules first appeared within 1 month of the start-up
Jin-zhou Zhu et al.
Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association, 27(12), 4323-4330 (2012-09-11)
Patients afflicted with chronic kidney disease (CKD) typically suffer from cardiovascular disease (CVD) which is a leading cause of patient mortality. It has been demonstrated that two distinct physiological events contribute to this disease state. These include the abundance of
S-T Huang et al.
Transplantation proceedings, 44(3), 621-624 (2012-04-10)
Uremic toxins are considered cardiovascular and mortality risk factors in chronic kidney disease (CKD) patients. Both p-cresol and indoxyl sulfate have been shown to induce oxidative stress in vitro and subsequent endothelial dysfunction in uremic patients. Our study evaluated the
Yu-Sen Peng et al.
Toxicology, 302(1), 11-17 (2012-07-21)
High serum levels of p-cresol have been associated with cardiovascular diseases. This study investigated the effects of p-cresol on gap junctions in neonatal cultured cardiomyocytes. p-Cresol reduced the spontaneous contraction rates of cardiomyocytes, and caused irregular cardiomyocyte beating. Junctional connexin
Michaël Carboni et al.
Inorganic chemistry, 51(19), 10447-10460 (2012-09-20)
The heterodinuclear complexes [Fe(III)Mn(II)(L-Bn)(μ-OAc)(2)](ClO(4))(2) (1) and [Fe(II)Mn(II)(L-Bn)(μ-OAc)(2)](ClO(4)) (2) with the unsymmetrical dinucleating ligand HL-Bn {[2-bis[(2-pyridylmethyl)aminomethyl]]-6-[benzyl-2-(pyridylmethyl)aminomethyl]-4-methylphenol} were synthesized and characterized as biologically relevant models of the new Fe/Mn class of nonheme enzymes. Crystallographic studies have been completed on compound 1 and

Artikel

Separation of 2-Chlorophenol; 2,4-Dichlorophenol; 2,4,6-Tribromophenol; 2,4,6-Trichlorophenol; 2,4-Dinitrophenol; Pentafluorophenol; 2-Methylphenol, analytical standard; 2,3,4,6-Tetrachlorophenol; Pentachlorophenol; 4-Nitrophenol; 2-Bromophenol; 2,3,5,6-Tetrachlorophenol; 2,3,5-Trichlorophenol; 4-Chloro-3-methylphenol; 2,4,5-Trichlorophenol; 4-Methylphenol, analytical standard; 2,4-Dimethylphenol; 2-Nitrophenol; 3-Methylphenol, analytical standard; Phenol; 2-Methyl-4,6-dinitrophenol; 2,3,4-Trichlorophenol; 2,6-Dichlorophenol; 2,3,4,5-Tetrachlorophenol

Protokolle

HPLC Analysis of Cresols and Phenol on Astec® CYCLOBOND® I 2000

GC Analysis of Xylene Isomers on SLB®-IL60

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..