QC1130
Demand-WP
certified reference material
Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise
Alle Fotos(1)
About This Item
Empfohlene Produkte
Qualität
certified reference material
Qualitätsniveau
Analysenzertifikat (CofA)
current certificate can be downloaded
Verpackung
ampule of 20 mL
Hersteller/Markenname
RTC QCI-026
Konzentration
100% in H2O
Methode(n)
TOC: suitable
Anwendung(en)
environmental
Format
matrix material
Lagertemp.
2-30°C
Verwandte Kategorien
Allgemeine Beschreibung
This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.
Anwendung
Das Produkt ist geeignet zur Messung von:
- Biochemischem Sauerstoffbedarf (BSB)
- Kohlenstoffhaltigem BOD (CBOD)
- Chemischem Sauerstoffbedarf (COD)
- Gelöstem organischen Kohlenstoff (DOC)
- Gesamtem organischen Kohlenstoff (TOC)
Angaben zur Herstellung
The solvent for this sample is water. This sample is packaged as a 20 mL concentrate. The sample has been autoclaved for preservation.
PREPARATION INSTRUCTIONS
To prepare solution, partially fill a 1-L volumetric flask with reagent-grade water. Open ampule QC1130-20ML (be careful to avoid cuts on glass) and transfer 10 mL from the ampule into the flask. Fill the volumetric flask to volume with reagent-grade water and mix well. The sample is now ready for immediate analysis.
Analyze the solution to determine BOD or CBOD first. If COD and TOC cannot be determined within two hours after sample preparation, an aliquot should be preserved (pH<2) using 0.2 mL of concentrated sulfuric acid per 100 mL. This aliquot should be stored at 4 degrees Celsius and analyzed as soon as possible within the 28-day maximum holding time.
NOTES: For proper oxygen depletion of BOD and CBOD, the sample should be tested in a dilution series. Use a natural surface water or diluted domestic sewage for seeded dilution water and avoid entrainment of air. For analysis of CBOD, the use of a nitrifying inhibitor is recommended. Be sure to determine the “blank” BOD of your seeded dilution water so that the proper seed correction can be made.
PREPARATION INSTRUCTIONS
To prepare solution, partially fill a 1-L volumetric flask with reagent-grade water. Open ampule QC1130-20ML (be careful to avoid cuts on glass) and transfer 10 mL from the ampule into the flask. Fill the volumetric flask to volume with reagent-grade water and mix well. The sample is now ready for immediate analysis.
Analyze the solution to determine BOD or CBOD first. If COD and TOC cannot be determined within two hours after sample preparation, an aliquot should be preserved (pH<2) using 0.2 mL of concentrated sulfuric acid per 100 mL. This aliquot should be stored at 4 degrees Celsius and analyzed as soon as possible within the 28-day maximum holding time.
NOTES: For proper oxygen depletion of BOD and CBOD, the sample should be tested in a dilution series. Use a natural surface water or diluted domestic sewage for seeded dilution water and avoid entrainment of air. For analysis of CBOD, the use of a nitrifying inhibitor is recommended. Be sure to determine the “blank” BOD of your seeded dilution water so that the proper seed correction can be made.
Sonstige Hinweise
Die Werte der Analyten sind Lot-spezifisch.
Analyt
Beschreibung
5-Day BOD 18 - 230 mg/L
Carbonaceous BOD (CBOD) 18 - 230 mg/L
Chemical oxygen demand (COD) 30 - 250 mg/L
Dissolved organic carbon (DOC) 6 - 100 mg/L
Total organic carbon (TOC) 6 - 100 mg/L
Lagerklassenschlüssel
12 - Non Combustible Liquids
WGK
nwg
Flammpunkt (°F)
Not applicable
Flammpunkt (°C)
Not applicable
Hier finden Sie alle aktuellen Versionen:
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Kunden haben sich ebenfalls angesehen
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.