Direkt zum Inhalt
Merck

46259

Supelco

1,1,2,2-Tetrachlorethan

analytical standard

Synonym(e):

Acetylentetrachlorid

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Lineare Formel:
CHCl2CHCl2
CAS-Nummer:
Molekulargewicht:
167.85
Beilstein:
969206
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
41116107
PubChem Substanz-ID:
NACRES:
NA.24

Qualität

analytical standard

Qualitätsniveau

Dampfdichte

5.8 (vs air)

Dampfdruck

8 mmHg ( 20 °C)

Haltbarkeit

limited shelf life, expiry date on the label

Methode(n)

HPLC: suitable
gas chromatography (GC): suitable

Brechungsindex

n20/D 1.494 (lit.)

bp

147 °C (lit.)

mp (Schmelzpunkt)

−43 °C (lit.)

Dichte

1.586 g/mL at 25 °C (lit.)

Anwendung(en)

environmental

Format

neat

Lagertemp.

2-8°C

SMILES String

ClC(Cl)C(Cl)Cl

InChI

1S/C2H2Cl4/c3-1(4)2(5)6/h1-2H

InChIKey

QPFMBZIOSGYJDE-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Anwendung

1,1,2,2-Tetrachloroethane may be used as an extraction solution for the simultaneous determination of chloramphenicol and thiamphenicol in honey samples using dispersive liquid-liquid microextraction followed by high-performance liquid chromatography.
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Piktogramme

Skull and crossbonesEnvironment

Signalwort

Danger

Gefahreneinstufungen

Acute Tox. 1 Dermal - Acute Tox. 2 Inhalation - Aquatic Chronic 2

Lagerklassenschlüssel

6.1A - Combustible acute toxic Cat. 1 and 2 / very toxic hazardous materials

WGK

WGK 3

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable

Persönliche Schutzausrüstung

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Choose from one of the most recent versions:

Analysenzertifikate (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Dispersive liquid--liquid microextraction followed by high-performance liquid chromatography as an efficient and sensitive technique for simultaneous determination of chloramphenicol and thiamphenicol in honey
Chen H, et al.
Analytica Chimica Acta, 632(1), 80-85 (2009)
Bahngmi Jung et al.
Chemosphere, 71(4), 726-734 (2007-12-11)
Transformation of 1,1,2,2-tetrachloroethane (1,1,2,2-TeCA) by Fe(II) in 10% cement slurries was characterized using a batch reactor system. 1,1,2,2-TeCA was completely converted to trichloroethylene (TCE) within 1h in all experiments, even in controls with cement that did not include Fe(II). Therefore
Maciej Bujak et al.
Chemical communications (Cambridge, England), 47(31), 8769-8771 (2011-05-28)
Directional Cl···Cl type I and II interactions govern the low-density aggregation of 1,1,2,2-tetrachloroethane molecules in synclinal conformation in the crystalline state at low temperature, whereas the dense molecular packing in high-pressure is achieved for the antiperiplanar conformers and electrostatically less
Jiaheng Zhang et al.
Talanta, 88, 330-337 (2012-01-24)
A novel pretreatment method termed ultrasound-assisted dispersive liquid-liquid microextraction (UADLLME) coupled with high-performance liquid chromatography-ultraviolet detector (HPLC-UV) was applied for the detection of four synthesized metabolites of mequindox in pig urine samples. A total volume of 200 μL of methanol
Simona Rossetti et al.
Biotechnology and bioengineering, 100(2), 240-249 (2008-04-24)
An anaerobic microcosm set up with aquifer material from a 1,1,2,2-tetrachloroethane (TeCA) contaminated site and amended with butyrate showed a complete TeCA dechlorination to ethene. A structure analysis of the microbial community was performed by fluorescence in situ hybridization (FISH)

Protokolle

US EPA Method TO-17: GC Analysis of Volatiles on VOCOL® after Collection/Desorption using Air Toxics Tube

US EPA Method 8260: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap, Fast GC Analysis

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.