Direkt zum Inhalt
Merck

SLSV0R25LS

Millipore

Millex® PVDF syringe filter

pore size 5.0 μm, diam. 25 mm, sterile, hydrophilic

Synonym(e):

Millex®-SV Filter Unit, low-binding syringe filter, particulate filter

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
41104922
NACRES:
NB.24

Materialien

PVC housing
PVDF membrane

Qualitätsniveau

Sterilität

ethylene oxide treated
sterile

Produktlinie

Millex®

Leistungsmerkmale

hydrophilic

Verpackung

pack of 50 ea

Hersteller/Markenname

Millex®

Methode(n)

low protein-binding filtration: suitable
sterile filtration: suitable

Durchmesser

25 mm

Filtrationsfläche

4 cm2

housing size

29 mm

inlet to outlet H

25 mm

Volumen

100 mL

Matrix

Durapore®

Porengröße

5.0 μm

Aufnahme

tissue culture medium
particle-laden solution(s)
aqueous solution(s)

Blasenpunkt

≥3 psi, water

Fitting

female Luer-Lok® inlet
male Luer outlet slip

Allgemeine Beschreibung

The bi-directionally supported Millex®-SV is a low-binding, syringe-operated filter for the filtration of aqueous, proteinaceous solutions where minimal sample loss is desired. It will remove particles, precipitates, and undissolved powders larger than 5.0 μm.

Spezifität

Materials

Membrane: Hydrophilic Durapore® polyvinylidene fluoride (PVDF), type SV
Pore size: 5.0 µm
Housing: Polyvinyl chloride (PVC)

Dimensions

Inlet to outlet: 25 mm (0.98 in.)
Diameter: 29 mm (1.14 in.)
Filtration: area 4 cm² (0.62 in2)
Temperature limit: 45 °C (113 °F)
Pressure limit at 21 °C: 5.2 bar (75 psi) inlet and differential
Filtration volume: 1–100 mL
Hold-up volume: ≤ 0.1 mL after air purge
Sterilization method: Ethylene oxide gas
Connections: Female Luer-Lok® inlet, male Luer-slip outlet
Flow rate at 2.1 bar (30 psi), 21 °C: ≥ 600 mL/min
Bubble point (water): ≥ 3 psi
Color: clear inlet, clear outlet

Anwendung

Syringe filter for particle or aggregate removal from protein solutions such as monoclonal antibodies, extracted cellular or tissue-based solutions, hormones, and reactive materials.

Leistungsmerkmale und Vorteile

  • Single use only
  • Low protein binding
  • Non-pyrogenic and non-toxic

Rechtliche Hinweise

Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany
Luer-Lok is a registered trademark of Becton-Dickinson & Co.
Millex is a registered trademark of Merck KGaA, Darmstadt, Germany

Ähnliches Produkt


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.