Direkt zum Inhalt
Merck

MABS1250

Sigma-Aldrich

Anti-Mineralocorticoid Receptor Antibody, clone 2D6

clone 2D6, from mouse

Synonym(e):

MR, Nuclear receptor subfamily 3 group C member 2, Mineralocorticoid Receptor

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
12352203
eCl@ss:
32160702
NACRES:
NA.43

Biologische Quelle

mouse

Qualitätsniveau

Antikörperform

purified immunoglobulin

Antikörper-Produkttyp

primary antibodies

Klon

2D6, monoclonal

Speziesreaktivität

rat

Methode(n)

immunocytochemistry: suitable
immunohistochemistry: suitable
western blot: suitable

Isotyp

IgG2aκ

NCBI-Hinterlegungsnummer

UniProt-Hinterlegungsnummer

Versandbedingung

wet ice

Posttranslationale Modifikation Target

unmodified

Angaben zum Gen

Allgemeine Beschreibung

Mineralocorticoid receptor (UniProt P22199; also known as MR, Nuclear receptor subfamily 3 group C member 2) is encoded by the Nr3c2 (also known as MCR, Mlr) gene (Gene ID 25672) in rats. Mineralocorticoid receptor (MR) is expressed in multiple tissues, including renal epithelia, smooth muscle, endothelium, cardiomyocytes, and hippocampal neurons, where it mediates diverse functions. MR is activated by aldosterone and also by cortisol in cells that do not express 11β-hydroxysteroid dehydrogenase type 2 (11βHSD2). MR is normally activated by aldosterone, which is produced by adrenal glomerulosa in response to intravascular volume depletion and hyperkalemia. Consistently, gain of function mutations in MR lead to severe hypertension, often with hypokalemia, while loss of function mutations result in neonatal hypotension. Ser843 phosphorylation in the MR ligand-binding domain is reported to prevent MR ligand binding and activation. MR pS843 is found exclusively in intercalated cells of the distal nephrons in the kidney. Intravascular volume depletion, angiotensin II and WNK4 signaling reduce MR pS843 levels, whereas hyperkalemia increases MR pS843.

Spezifität

Epitope is present in all 3 alternative spliced isoforms

Immunogen

Conjugated linear peptide corresponding to the N-terminus of rat Mineralocorticoid Receptor.
Epitope: Near N-terminus

Anwendung

Research Category
Zelluläre Signaltransduktion
Research Sub Category
Signalübertragung & Neurowissenschaft
Detect Mineralocorticoid Receptor using this Anti-Mineralocorticoid Receptor Antibody, clone 2D6 validated for use in Western Blotting, Immunohistochemistry and Immunocytochemistry.
Immunohistochemistry Analysis: A representative lot detected Mineralocorticoid Receptor in hippocampus, dentate gyrate, choroid plexus, heart, and rat kidney (Gomez-Sanchez, C.E., et al. (2006). Endocrinology. 147(3):1343-1348).
Immunocytochemistry Analysis: A representative lot detected Mineralocorticoid Receptor in mouse kidney (Shibata, S., et al. (2013). Cell Metabolism. 18:660-671).
Western Blotting Analysis: A representative lot detected endogenous Mineralocorticoid Receptor (MR) in rat hippocampal cytosolic preparation and exogenously expressed EGFP-rat MR fusion protein in CHO cells (Gomez-Sanchez, C.E., et al. (2006). Endocrinology. 147(3):1343-1348).
Western Blotting Analysis: A representative lot detected endogenous Mineralocorticoid Receptor (MR) in mouse kidney cytosolic fraction and exogenously expressed human MR in COS-7 cells (Shibata, S., et al. (2013) Cell Metab. 18(5):660-671)

Qualität

Evaluated by Western Blotting in rat brain cytosol tissue lysate.

Western Blotting Analysis: A 1:500 dilution of this antibody detected Mineralocorticoid Receptor in 10 µg of rat brain cytosol tissue lysate.

Zielbeschreibung

~107 kDa observed

Physikalische Form

Protein G Purified
Format: Purified
Purified mouse monoclonal IgG2aκ in buffer containing 0.1 M Tris-Glycine (pH 7.4), 150 mM NaCl with 0.05% sodium azide.

Lagerung und Haltbarkeit

Stable for 1 year at 2-8°C from date of receipt.

Sonstige Hinweise

Concentration: Please refer to lot specific datasheet.

Haftungsausschluss

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Sie haben nicht das passende Produkt gefunden?  

Probieren Sie unser Produkt-Auswahlhilfe. aus.

Lagerklassenschlüssel

12 - Non Combustible Liquids

WGK

WGK 1

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.