Millipore Express® SHF, Opticap® XL Kapsel

Opticap® XL 150, sterile, inlet connection diam. 9/16 in., cartridge nominal length 3.8 in. (9.7 cm)

Synonym(e):

Opticap XL 150 Millipore Express SHF Sterile 0.2 μm 9/16 in. HB/HB

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
23151806

Materialien

polyethersulfone
polyethylene support
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap
polysulfone
silicone seal

Qualitätsniveau

Einhaltung gesetzlicher Vorschriften

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

Sterilität

irradiated
sterile

Produktlinie

Opticap® XL 150

Leistungsmerkmale

hydrophilic

Hersteller/Markenname

Millipore Express®

Parameter

≤1.4 mL/min air diffusion at 2.8 bar (40 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure

Methode(n)

sterile filtration: suitable

Länge

9.7 cm (3.8 in.)

Nennlänge Kartusche

3.8 in. (9.7 cm)

Durchmesser

5.6 cm (2.2 in.)

Filtrationsfläche

220 cm2

Durchm. Einlassanschluss

9/16 in.

Breite Einlass bis Auslass

9.7 cm (3.8 in.)

Durchm. Auslassanschluss

9/16 in.

Verunreinigungen

≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

Matrix

Millipore Express® SHF

Porengröße

0.2 μm

Blasenpunkt

≥4000 mbar (58 psig), air with water at 23 °C

Fitting

1/4 in. drain/vent hose barb (with double O-ring seal)
inlet hose barb
outlet hose barb
(14 mm (9/16 in.) Hose Barb Inlet and Outlet)

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Device Configuration: Filtereinheit
Sterile capsules meet current USP and AAMI guidelines for sterility utilizing a validated sterilization cycle.

Verpackung

Double Easy-Open bag

Sonstige Hinweise

Diese Produkte werden in einem Werk hergestellt, das den GMP-Richtlinien der FDA entspricht.
Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Angaben zur Herstellung

Sterilization Method
3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Hinweis zur Analyse

Bacterial Retention
Quantitative Rückhaltung von Brevundimonas diminuta bei einer Mindestbeaufschlagung von 1 x 10⁷ KBE/cm² unter Anwendung der ASTM® F838-Methode.
Erfüllt die Anforderungen des USP-Tests auf oxidierbare Substanzen nach Durchspülen mit ≥1 l Wasser
TOC/Conductivity
After sterilization and a controlled water flush of 2.0 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.

Rechtliche Hinweise

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Haftungsausschluss

EMD Millipore Corporation bestätigt, dass dieses Produkt der europäischen Druckgeräterichtlinie 97/23/EG vom 29. Mai 1997 entspricht. Dieses Produkt wurde unter Artikel 3 § 3 der Druckgeräterichtlinie klassifiziert. Das Produkt wurde in Übereinstimmung mit anerkannten technischen Methoden entwickelt und hergestellt, um einen sicheren Betrieb zu gewährleisten. In Konformität mit Artikel 3 § 3 dieser Druckgeräterichtlinie besitzt dieses Produkt kein CE-Zeichen.

Sie haben nicht das passende Produkt gefunden?  

Probieren Sie unser Produkt-Auswahlhilfe. aus.


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.