CVEP72TS3
Millipore Express® SHR, Cartridge
pore size 0.1 μm, cartridge nominal length 20 in. (50 cm), Code 7, silicone seal
Synonym(e):
Millipore Express SHR Cartridge Filter 20 in. 0.1 μm Code 7 Silicone
About This Item
Empfohlene Produkte
Materialien
polyethersulfone
polypropylene
polypropylene support
polysulfone
silicone seal
Qualitätsniveau
Einhaltung gesetzlicher Vorschriften
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
Sterilität
non-sterile
Kompatibilität mit Sterilisationsverfahren
autoclavable compatible
steam-in-place compatible
Produktlinie
Millipore Express®
Leistungsmerkmale
hydrophilic
Hersteller/Markenname
Millipore Express®
Parameter
≤66.6 mL/min air diffusion at 3.45 bar (50 psig) and 23 °C (in water)
<1.0 psi max. differential pressure (69 mbar) at 135 °C (reverse)
0.07 bar max. differential pressure (1 psi) at 135 °C (Reverse)
0.35 bar max. differential pressure (5 psi) at 135 °C (Forward)
1.7 bar max. differential pressure (25 psi) at 80 °C (Forward)
100 psi max. differential pressure (6.9 bar) at 25 °C (forward)
2.07 bar max. differential pressure (30 psi) at 25 °C (Reverse)
25 psi max. differential pressure (1.7 bar) at 80 °C (forward)
30 psi max. differential pressure (2.1 bar) at 25 °C (reverse)
5.0 psi max. differential pressure (340 mbar) at 135 °C (forward)
6.9 bar max. differential pressure (100 psi) at 25 °C (Forward)
Methode(n)
sterile filtration: suitable
Länge
20 in.
Breite
2.7 in.
Nennlänge Kartusche
20 in. (50 cm)
Durchmesser
6.9 cm (2.7 in.)
Filtrationsfläche
1.2 m2
Verunreinigungen
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Matrix
Millipore Express® SHR
Porengröße
0.1 μm pore size
Aufnahme
sample type liquid
Blasenpunkt
≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water at 23 °C
Kartuschencode
Code 7
Allgemeine Beschreibung
Verpackung
Sonstige Hinweise
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer wetting instructions of Filters with MILLIPORE EXPRESS® Membrane user guide
- Storage Statement: Please refer Filters with MILLIPORE EXPRESS® Membrane user guide
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Angaben zur Herstellung
25 forward or 22 forward and 3 reverse SIP cycles of 30 min @ 135 °C; 25 autoclave cycles of 60 min @ 126 °C
Hinweis zur Analyse
Quantitative Rückhaltung von Brevundimonas diminuta bei einer Mindestbeaufschlagung von 1 x 10⁷ KBE/cm² unter Anwendung der ASTM® F838-Methode.
After sterilization and a controlled water flush of 20 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Rechtliche Hinweise
Not finding the right product?
Try our Produkt-Auswahlhilfe.
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.