Direkt zum Inhalt
Merck

CHVE71TE3

Millipore

Millipore Express® SHRP, Kartusche

pore size 0.5/0.1 μm, cartridge nominal length 10 in. (25 cm), Code 7, EPDM rubber seal

Synonym(e):

Millipore Express SHR Cartridge Filter 10 in. 0.5/0.1 μm Code 7 EPDM

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
23151806
eCl@ss:
32031690

Materialien

EPDM rubber seal
polyethersulfone
polypropylene
polypropylene support
polysulfone

Qualitätsniveau

Einhaltung gesetzlicher Vorschriften

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

Sterilität

non-sterile

Kompatibilität mit Sterilisationsverfahren

autoclavable compatible
steam-in-place compatible

Produktlinie

Millipore Express®

Leistungsmerkmale

hydrophilic

Hersteller/Markenname

Millipore Express®

Parameter

≤27.1 mL/min air diffusion at 3.45 bar (50 psig) and 23 °C (in water)
<1.0 psi max. differential pressure (69 mbar) at 135 °C (reverse)
0.07 bar max. differential pressure (1 psi) at 135 °C (Reverse)
0.35 bar max. differential pressure (5 psi) at 135 °C (Forward)
1.7 bar max. differential pressure (25 psi) at 80 °C (Forward)
100 psi max. differential pressure (6.9 bar) at 25 °C (forward)
15 psi max. differential pressure (1.0 bar) at 135 °C (forward)
2.07 bar max. differential pressure (30 psi) at 25 °C (Reverse)
25 psi max. differential pressure (1.7 bar) at 80 °C (forward)
30 psi max. differential pressure (2.1 bar) at 25 °C (reverse)
6.9 bar max. differential pressure (100 psi) at 25 °C (Forward)

Methode(n)

sterile filtration: suitable

Länge

10 in.

Breite

2.7 in.

Nennlänge Kartusche

10 in. (25 cm)

Durchmesser

6.9 cm (2.7 in.)

Filtrationsfläche

0.48 m2

Verunreinigungen

≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

Matrix

Millipore Express® SHR (w/Prefilter)

pore size

0.5/0.1 μm pore size

Aufnahme

sample type liquid

Blasenpunkt

≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water at 23 °C

Kartuschencode

Code 7

Allgemeine Beschreibung

Device Configuration: Filterelement

Verpackung

Leicht zu öffnender Doppelbeutel

Sonstige Hinweise

Diese Produkte werden in einem Werk hergestellt, das den GMP-Richtlinien der FDA entspricht.
Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer wetting instructions of Filters with MILLIPORE EXPRESS® Membrane user guide
  • Storage Statement: Please refer Filters with MILLIPORE EXPRESS® Membrane user guide
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Angaben zur Herstellung

Sterilization Method
25 forward or 22 forward and 3 reverse SIP cycles of 30 min @ 135 °C, or 3 forward cycles, 30 min., 135 °C at ≤ 1000 mbar (15 psid); 25 autoclave cycles of 60 min @ 126 °C
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Hinweis zur Analyse

Bacterial Retention
Quantitative Rückhaltung von Brevundimonas diminuta bei einer Mindestbeaufschlagung von 1 x 10⁷ KBE/cm² unter Anwendung der ASTM® F838-Methode.
Erfüllt die Anforderungen des USP-Tests auf oxidierbare Substanzen nach Durchspülen mit ≥2 l Wasser
TOC/Conductivity
After sterilization and a controlled water flush of 20 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.

Rechtliche Hinweise

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany

Sie haben nicht das passende Produkt gefunden?  

Probieren Sie unser Produkt-Auswahlhilfe. aus.


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.