Direkt zum Inhalt
Merck

669431

Sigma-Aldrich

Lithiumfluorid

Precipitated, 99.995%

Synonym(e):

Fluorolithium

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Lineare Formel:
LiF
CAS-Nummer:
Molekulargewicht:
25.94
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
12352302
PubChem Substanz-ID:
NACRES:
NA.23

Qualitätsniveau

Assay

99.995%

Form

powder

Verunreinigungen

≤55.0 ppm Trace Metal Analysis

mp (Schmelzpunkt)

845 °C (lit.)

Dichte

2.64 g/mL at 25 °C (lit.)

SMILES String

[Li+].[F-]

InChI

1S/FH.Li/h1H;/q;+1/p-1

InChIKey

PQXKHYXIUOZZFA-UHFFFAOYSA-M

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Lithium fluoride is an inorganic halide with good ionic conductivity, high refractive index, and high transmittance in the UV region. Owing to its unique properties, it is widely used in the field of optical and electronic devices, X-ray imaging, and dental materials.

Anwendung

Lithium fluoride(LiF) can be used:
  • To fabricate an insulating layer in AC-driven organic light-emitting diodes(OLEDs). LiF provides excellent capacitance and high stability to the insulating layers in AC devices.
  • As a precursor to synthesize Eu2+/Ce3+ doped barium lithium fluoride phosphors by solvothermal method.
  • To fabricate LiF thin film coating on the lithium anodes to enhance their stability and coulombic efficiency.
  • As an additive to enrich and enhance the performance of solidelectrolyte interface(SEI) in Li metal batteries.

Piktogramme

Skull and crossbones

Signalwort

Danger

Gefahreneinstufungen

Acute Tox. 3 Oral - Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

Zielorgane

Respiratory system

Zusätzliche Gefahrenhinweise

Lagerklassenschlüssel

6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

WGK

WGK 2

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable

Persönliche Schutzausrüstung

Eyeshields, Faceshields, Gloves, type P2 (EN 143) respirator cartridges


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Hatem Dachraoui et al.
Optics express, 19(3), 2797-2804 (2011-03-04)
We report a femtosecond crystallographic study of the dependence of the free-carries generation to the alignment of a crystalline sample to the laser polarization. The probe pulse transmission exhibits a π/2 modulation that is shown to be correlated with the
R Takam et al.
Radiation protection dosimetry, 150(1), 22-33 (2011-08-30)
(6)LiF:Mg,Cu,P and (7)LiF:Mg,Cu,P glass-rod thermoluminescent dosemeters (TLDs) were used for measurements of out-of-field photon and neutron doses produced by Varian iX linear accelerator. Both TLDs were calibrated using 18-MV X-ray beam to investigate their dose-response sensitivity and linearity. CR-39 etch-track
Thorsten Grünheid et al.
American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics, 141(4), 436-443 (2012-04-03)
Cone-beam computed tomography (CBCT) has become a routine imaging modality for many orthodontic clinics. However, questions remain about the amount of radiation patients are exposed to during the scans. This study determined the amounts of radiation potentially absorbed by a
Christian Bernhardsson et al.
Health physics, 103(6), 740-749 (2012-11-01)
Laboratory studies have shown that ordinary household salt (NaCl) exhibits several promising properties for retrospective dosimetry; e.g., a linear dose response and a low detection limit, down to a few mGy or even less. In an attempt to test NaCl
Igor Rahinov et al.
Physical chemistry chemical physics : PCCP, 13(28), 12680-12692 (2011-06-17)
The Born-Oppenheimer Approximation (BOA) forms the basis for calculating electronically adiabatic potential energy surfaces, thus providing the framework for developing a molecular level understanding of a variety of important chemical problems. For surface chemistry at metal surfaces, it is now

Artikel

Professor Gogotsi and Dr. Shuck introduce MXenes: a promising family of two-dimensional materials with a unique combination of high conductivity, hydrophilicity, and extensive tunability.

Research and development of solid-state lithium fast-ion conductors is crucial because they can be potentially used as solid electrolytes in all-solid-state batteries, which may solve the safety and energy-density related issues of conventional lithium-ion batteries that use liquid (farmable organic) electrolytes.

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.