Saltar al contenido
MilliporeSigma

Aroma volatiles from stored apples

Aroma volatiles from stored apples suitable for GC, application for SPME

Materiales

analytical column

Referencia del producto
Descripción
Precios

SLB®-5ms Capillary GC Column

L × I.D. 30 m × 0.25 mm, df 0.50 μm

Related product

Referencia del producto
Descripción
Precios

Portafibra SPME

for use with manual sampling

Portafibra SPME

for use with CTC CombiPAL and Gerstel MPS2

SPME fiber

Referencia del producto
Descripción
Precios

SPME fiber assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB)

df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder

standard

Referencia del producto
Descripción
Precios

Hexyl acetate

analytical standard

Butyl acetate

analytical standard

Isoamyl acetate

natural, ≥97%, FCC, FG

2-Metil-1-butanol

≥99%

Hexyl 2-methylbutanoate

analytical standard

Hexyl hexanoate

analytical standard

CONDITIONS

sample/matrix

300-450g intact fruit in a 3 liter flask at ambient temp, exposed to an air flow of 25-30 mL/min

SPME fiber

polydimethylsiloxane, 100 μm film (57310-U)

desorption process

250°C for 90 sec

column

5% phenyl polysiloxane, 25m × 0.25 mm I.D., 0.34 μm film (Supelco equivalent, SLB-5ms, 28473-U)

oven

40 °C (1.5 min) to 250 °C at 50 °C/min, hold 1 min

inj. temp.

250 °C

detector

mass spectrometer, m/z = 40-300 (40 spectra/sec)

carrier gas

helium, 1.5 mL/min (44 cm/min)

sample

Apples

Descripción

Analysis Note

SPME can reduce sampling time and is complementary to rapid separation/detection techniques such as time compressed gas chromatography (TCGC) and time-of-flight mass spectrometry (TOF-MS), to permit analysis of dozens of compounds in a few minutes. Investigators have used SPME to monitor flavor volatiles in apple, strawberry, tomato, and many other fruits and vegetables. In this application, 65 μm PDMS/divinylbenzene (DVB) SPME fibers were used to capture volatiles emanating from Mutsu apples stored for 3-4 months at 0 °C.