跳轉至內容
Merck

GC Analysis of Resveratrol in Red Wine (Spiked) on SLB®-5ms after SPME using a 85 μm Polyacrylate Fiber

GC Analysis of Resveratrol in Red Wine (Spiked) on SLB®-5ms after SPME using a 85 μm Polyacrylate Fiber suitable for GC, application for SPME

材料

分析柱

產品號碼
描述
訂價

SLB ®-5 ms 毛细管 GC 色谱柱

L × I.D. 30 m × 0.25 mm, df 0.25 μm

固相微萃取纖維

產品號碼
描述
訂價

聚丙烯酸酯 (PA) 固相微萃取萃取头

df 85 μm(PA, for use with manual holder, needle size 24 ga

聚丙烯酸酯 (PA) 固相微萃取萃取头

df 85 μm(PA, for use with autosampler, needle size 24 ga

聚丙烯酸酯 (PA) 固相微萃取萃取头

df 85 μm(PA, for use with autosampler, needle size 23 ga

標準

產品號碼
描述
訂價

白藜芦醇

≥99% (HPLC)

相關產品

產品號碼
描述
訂價

SPME 光纤支架

for use with manual sampling

SPME 光纤支架

for use with CTC CombiPAL and Gerstel MPS2

进样口衬管,直接 (SPME) 型,直型设计(未包装)

pkg of 1 ea

附屬品

產品號碼
描述
訂價

预组装螺纹口样品瓶,带酚醛树脂顶部开口瓶盖

volume 4 mL, clear glass vial, O.D. × H 15 mm × 45 mm, tan PTFE/silicone septum

CONDITIONS

sample/matrix

3 mL of red wine (California merlot) spiked with resveratrol at 100 μg/L then diluted 3:1 in 12% ethanol:water

SPME fiber

85 μm polyacrylate (57304, 57305, 57294-U)

extraction

immersion for 15 min at room temperature while stirring at 400 rpm, fiber gently blotted with a Kimwipe to remove excess water, (then derivatization by immersion in a 4 mL vial containing 5 μL of Sylon-BFT (fresh vial for each analysis than was allowed to equilabrate 60-90 minutes prior to use) for 20 min)

desorption process

280 °C for 2 min

column

SLB-5ms; 30 m x 0.25 mm I.D., 0.25 μm (28471-U)

oven

100 °C (1 min), 10 °C/min to 325 °C (3 min)

inj. temp.

280 °C

detector

GC/MS

MSD interface

325 °C

scan range

m/z 40-450

carrier gas

helium, 1 mL/min, constant

liner

0.75 mm I.D., SPME

sample

Red wine

描述

分析報告

In this study, the extraction and analysis of resveratrol from red wine is demonstrated using solid phase microextraction (SPME) and GC/MS. The presence of three hydroxyl (OH) groups makes it necessary to derivatize this compound prior to GC analysis. Derivatization was conducted, after extraction, directly on the SPME fiber by exposing it to the vapors of a silyating reagent. The derivative of resveratrol was then analyzed directly from the fiber using GC/MS. The polyacrylate fiber, which is suitable for the extraction of polar semivolatiles and is more resistant to swelling than other types of fibers was used in the analysis. The SLB-5ms GC columns provide consistently low-bleed, inert, efficient, and durable separations.

法律資訊

SLB is a registered trademark of Merck KGaA, Darmstadt, Germany