跳轉至內容
Merck
  • A method for quantification of volatile organic compounds in blood by SPME-GC-MS/MS with broader application: From non-occupational exposure population to exposure studies.

A method for quantification of volatile organic compounds in blood by SPME-GC-MS/MS with broader application: From non-occupational exposure population to exposure studies.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2015-05-13)
Rocio Aranda-Rodriguez, Ashley Cabecinha, Jeromy Harvie, Zhiyun Jin, Axelle Marchand, Robert Tardif, Andy Nong, Sami Haddad
摘要

Humans are continuously exposed to volatile organic compounds (VOCs) as these chemicals are ubiquitously present in most indoor and outdoor environments. In order to assess recent exposure to VOCs for population-based studies, VOCs are measured in the blood of participants. This work describes an improved method to detect 12 VOCs by head-space solid-phase microextraction gas chromatography coupled with isotope-dilution mass spectrometry in selected reaction monitoring mode (SPME-GC-MS/MS). This method was applied to the analysis of trihalomethanes, styrene, trichloroethylene, tetrachloroethylene and BTEX (benzene, toluene, ethylbenzene, m-xylene, p-xylene, o-xylene) in a population-based biomonitoring study (Canadian Health Measures Survey). The method showed good linearity (>0.990) in the range of 0.010-10μg/L and detection limits between 0.007 and 0.027μg/L, precision better than 25% and good accuracy (±25%) based on proficiency testing materials. Quality Control data among runs over a 7 month period showed %RSD between 14 and 25% at low levels (∼0.03μg/L) and between 9 and 23% at high levels (∼0.4μg/L). The method was modified to analyze samples from a pharmacokinetic study in which 5 healthy volunteers were exposed to single, binary and quaternary mixtures of CTEX (chloroform, ethylbenzene, toluene and m-xylene), thus the expected concentration in blood was 1 order of magnitude higher than those found in the general population. The method was modified by reducing the sample size (from 3g to 0.5g) and increasing the upper limit of the concentration range to 395μg/L. Good linearity was found in the range of 0.13-395μg/L for toluene and ethylbenzene and 0.20-609μg/L for m/p-xylene. Quality control data among runs over the period of the study (n=13) were found to vary between 7 and 25%.

材料
產品編號
品牌
產品描述

Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
氟化钠, 99.99% trace metals basis
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Sigma-Aldrich
苯乙烯, ReagentPlus®, contains 4-tert-butylcatechol as stabilizer, ≥99%
Sigma-Aldrich
苯, anhydrous, 99.8%
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
聚丙烯酸酯 (PA) 固相微萃取萃取头, df 85 μm(PA, for use with autosampler, needle size 23 ga
Sigma-Aldrich
氟化钠溶液
Sigma-Aldrich
氟化钠, BioReagent, suitable for insect cell culture, ≥99%
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
聚丙烯酸酯 (PA) 固相微萃取萃取头, df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with autosampler
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Sigma-Aldrich
大黄酸, technical grade
Supelco
固相微萃取 StableFlex 萃取头组合套件, for use with manual holder
Sigma-Aldrich
氟化钠, BioXtra, ≥99%
Sigma-Aldrich
大黄酸
Supelco
Carbowax-聚乙二醇 (PEG) 固相微萃取萃取头, needle size 23 ga, df 60 μm(PEG, for use with autosampler
Supelco
固相微萃取 StableFlex 萃取头组合套件, needle size 23 ga, for use with autosampler
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), fused silica fiber, df 65 μm(PDMS/DVB, for use with manual holder, needle size 23 ga
Sigma-Aldrich
甲醇, NMR reference standard
Supelco
聚丙烯酸酯 (PA) 固相微萃取萃取头, df 85 μm(PA, for use with manual holder, needle size 24 ga
Sigma-Aldrich
四氯乙烯, anhydrous, ≥99%
Supelco
SPME 纤维分类套件 4, for use with manual holder, size 24 ga
Supelco
Carbowax-聚乙二醇 (PEG) 固相微萃取萃取头, needle size 23 ga, df 60 μm(PEG, metal alloy fiber, for use with manual holder