跳轉至內容
Merck
  • Screening for petrochemical contamination in seafood by headspace solid-phase microextraction gas chromatography-mass spectrometry.

Screening for petrochemical contamination in seafood by headspace solid-phase microextraction gas chromatography-mass spectrometry.

Analytical and bioanalytical chemistry (2015-03-23)
F Aladar Bencsath, Ronald A Benner, Ann Abraham, Yuesong Wang, Kathleen R El Said, Edward L E Jester, Steven M Plakas
摘要

A headspace solid-phase microextraction gas chromatography-mass spectrometry (SPME GC-MS) method is described, to screen seafood for volatile organic compounds (VOCs) associated with petrochemical taint. VOCs are extracted from the headspace of heated sample homogenates by adsorption onto a SPME fiber and desorbed for analysis by GC-MS. Targeted compounds are determined semi-quantitatively using representative calibration standards for the various classes (alkanes, alkylbenzenes, indanes/tetralins, and naphthalenes) of VOCs analyzed. Sample preparation is minimal, and the analyses are rapid and automated with a capacity of 50 samples per day. The method was optimized in terms of headspace temperature, sample heating time, extraction time, and desorption time using oyster samples fortified with target compounds. Calibrations for hydrocarbon components were linear in the range of 8.3-167 ng/g; the limit of detection ranged between 0.05 and 0.21 ng/g, and the limit of quantitation between 0.16 and 0.69 ng/g. Good precision (RSD < 10 % at 16.7 ng/g for individual VOCs) and accuracy (recovery range 89-118 % at 25 ng/g) were obtained in oyster, crab, shrimp, and finfish matrices. The trueness of the method was demonstrated by quantifying VOCs at 1-2-ppb levels in oyster fortified with certified reference material NIST SRM 1491a. Following single laboratory validation, the method was employed for the determination of VOCs in seafood exposed to oil contaminated seawater and for the determination of background VOC levels in seafood species from the Gulf of Mexico and local food stores. The method as described can be used to supplement human sensory testing for petrochemical taint in seafood.

材料
產品編號
品牌
產品描述

Sigma-Aldrich
萘, 99%
Sigma-Aldrich
十四烷, ≥99%
Sigma-Aldrich
Triton X-100, laboratory grade
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Sigma-Aldrich
十四烷, olefin free, ≥99.0% (GC)
Sigma-Aldrich
1-甲基萘, 95%
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Sigma-Aldrich
十三烷, ≥99%
Sigma-Aldrich
萘-d8, 99 atom % D, ≥98% (CP)
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Sigma-Aldrich
萘, suitable for scintillation, ≥99%
Supelco
聚丙烯酸酯 (PA) 固相微萃取萃取头, df 85 μm(PA, for use with autosampler, needle size 23 ga
Sigma-Aldrich
均三甲苯, 98%
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Sigma-Aldrich
对二甲苯, anhydrous, ≥99%
Supelco
聚丙烯酸酯 (PA) 固相微萃取萃取头, df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with autosampler
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
固相微萃取 StableFlex 萃取头组合套件, for use with manual holder
Sigma-Aldrich
茚满, 95%
Sigma-Aldrich
均三甲苯, reagent grade, 97%
Supelco
Carbowax-聚乙二醇 (PEG) 固相微萃取萃取头, needle size 23 ga, df 60 μm(PEG, for use with autosampler
Supelco
固相微萃取 StableFlex 萃取头组合套件, needle size 23 ga, for use with autosampler
Sigma-Aldrich
2,6-二甲基萘, 99%
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), fused silica fiber, df 65 μm(PDMS/DVB, for use with manual holder, needle size 23 ga
Sigma-Aldrich
1-甲基萘, ≥95%