跳轉至內容
Merck
  • Determination of low levels of benzodiazepines and their metabolites in urine by hollow-fiber liquid-phase microextraction (LPME) and gas chromatography-mass spectrometry (GC-MS).

Determination of low levels of benzodiazepines and their metabolites in urine by hollow-fiber liquid-phase microextraction (LPME) and gas chromatography-mass spectrometry (GC-MS).

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-12-03)
André Valle de Bairros, Rafael Menck de Almeida, Lorena Pantaleão, Thiago Barcellos, Sidnei Moura e Silva, Mauricio Yonamine
摘要

In this study, it is shown a method for the determination of benzodiazepines and their main metabolites in urine samples by hollow-fiber liquid-phase microextraction (LPME) in the three-phase mode. Initially, the hydrolysis step was performed using 100 μL of sodium acetate 2.0 mol/L buffer solution (pH 4.5), 25 μL of β-glucuronidase enzyme and incubation for 90 min at 55 °C. In parallel with hydrolysis, the LPME fiber (9 cm) was prepared. Its pores were filled with a mixture of dihexyl ether: 1-nonanol (9:1). Afterwards, a solution of 3.0 mol/L of HCl was introduced into the lumen of the fiber (acceptor phase). After hydrolysis, the fiber was submersed in the alkalinized urine (pH 10) containing 10% NaCl. Samples were then submitted to orbital shaking (2400 rpm) for 90 min. The acceptor phase was later withdrawn from the fiber, dried and the residue derivatized with trifluoroacetic anhydride (TFAA) for 10 min at 60 °C with further addition of N-methyl-N-tert-butyldimethylsilyltrifluoroacetamide containing 1% tert-butyldimethylchlorosilane (MTBSTFA) for 45 min at 90 °C followed by determination by gas chromatography-mass spectrometry (GC-MS). The calibration curves obtained showed linearity over the specified range, with a similar sensitivity to traditional techniques and a higher detection capability compared to most of the miniaturized methods described in the literature. The method has been developed and successfully validated and applied to urine samples from real cases of benzodiazepines intake.

材料
產品編號
品牌
產品描述

Sigma-Aldrich
盐酸, ACS reagent, 37%
Sigma-Aldrich
乙酸乙酯, ACS reagent, ≥99.5%
Sigma-Aldrich
氢氧化钠, ACS reagent, ≥97.0%, pellets
Sigma-Aldrich
乙酸乙酯, suitable for HPLC, ≥99.7%
Sigma-Aldrich
盐酸, ACS reagent, 37%
Sigma-Aldrich
氢氧化钠, reagent grade, ≥98%, pellets (anhydrous)
Sigma-Aldrich
2 mol/L 氢氧化钠溶液 溶液, 50% in H2O
Sigma-Aldrich
氯化氢 溶液, 4.0 M in dioxane
Sigma-Aldrich
乙酸乙酯, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
乙酸钠, anhydrous, ReagentPlus®, ≥99.0%
Sigma-Aldrich
2 mol/L 氢氧化钠溶液 溶液, BioUltra, for molecular biology, 10 M in H2O
Sigma-Aldrich
乙酸钠, ACS reagent, ≥99.0%
Sigma-Aldrich
盐酸 溶液, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
乙酸钠, puriss. p.a., ACS reagent, reag. Ph. Eur., anhydrous
Sigma-Aldrich
氢氧化钠, BioXtra, ≥98% (acidimetric), pellets (anhydrous)
Sigma-Aldrich
2 mol/L 氢氧化钠溶液 溶液, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
盐酸, meets analytical specification of Ph. Eur., BP, NF, fuming, 36.5-38%
Sigma-Aldrich
氢氧化钠, puriss., meets analytical specification of Ph. Eur., BP, NF, E524, 98-100.5%, pellets
Sigma-Aldrich
盐酸, 37 wt. % in H2O, 99.999% trace metals basis
Sigma-Aldrich
氧氯化锆 八水合物, reagent grade, 98%
Sigma-Aldrich
氢氧化钠, reagent grade, 97%, powder
Sigma-Aldrich
盐酸, 36.5-38.0%, BioReagent, for molecular biology
Sigma-Aldrich
盐酸, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., fuming, ≥37%, APHA: ≤10
Sigma-Aldrich
氯化氢 溶液, 2.0 M in diethyl ether
Sigma-Aldrich
氢氧化钠, pellets, semiconductor grade, 99.99% trace metals basis
Sigma-Aldrich
氢氧化钠, puriss. p.a., ACS reagent, reag. Ph. Eur., K ≤0.02%, ≥98%, pellets
Sigma-Aldrich
1-辛醇, ACS reagent, ≥99%
Sigma-Aldrich
乙酸乙酯, suitable for HPLC, ≥99.8%
Supelco
盐酸 溶液, volumetric, 0.1 M HCl (0.1N), endotoxin free
Sigma-Aldrich
丁基二甲基氯硅烷, reagent grade, 97%