跳轉至內容
Merck
全部照片(1)

Key Documents

575664-U

Supelco

Supel-Select SCX SPE 96-well Plate

bed wt. 30 mg/well, pk of 1

登入查看組織和合約定價


About This Item

分類程式碼代碼:
41104018
NACRES:
NB.21

材料

PE frit (20 μm)
polypropylene hardware

品質

MS Friendly

成份

bed wt., 30 mg/well

包裝

pk of 1

技術

solid phase extraction (SPE): suitable

表面積

160-420 m2/g

基質

Sulfonic acid functionalized hydrophilic modified styrene polymer particle platform

基質活性組

sulfonic acid phase

粒徑

50-70 μm

孔徑

80-200 Å pore size

應用

food and beverages

分離技術

ion exchange

尋找類似的產品? 前往 產品比較指南

一般說明

Retention Mechanism: Ion-Exchange
Sample Matrix Compatibility: Aqueous solutions (biological fluids, water)

  • Sulfonic acid functionalized hydrophilic modified styrene polymer
  • Developed for the extraction of a highly broad range of compounds from aqueous samples
  • Retention predominately based on ion-exchange; however, because the phase is hydrophilic modified, it is amenable to polar compounds as well.

特點和優勢

  • 价格低廉但具有出色的样品制备性能
  • 可用于通用方法 — 在方法开发时省时、成本低并减少麻烦
  • 容量更大,床重更轻 = 洗脱体积更小 = 处理样品更迅速
  • 能忍受过度干涸,可用于更极端条件的方法
  • 低紫外和质谱可提取物,背景更低,灵敏度更高
  • 严格的生产和质量控制原则提供更好的批次之间、管之间以及孔之间的一致性,能获得更好的准确度和精度

法律資訊

Supel is a trademark of Sigma-Aldrich Co. LLC

象形圖

Exclamation mark

訊號詞

Warning

危險聲明

危險分類

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

標靶器官

Respiratory system

儲存類別代碼

11 - Combustible Solids

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

未看到正確版本?

如果您需要一個特定的版本,您可以透過批號來尋找特定憑證。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

文章

Shown here is the chiral separation of amphetamine enantiomers under MS-compatible conditions on Astec CHIROBIOTIC® V2 after extraction from urine using Supel™-Select SCX SPE 96-well plates. The highest grade mobile phase solvents and additives were used to supply low background interference and low particulate contaminants for robust, trouble-free operation. Cerilliant CRMs provided reliable identification and quantification.

Separation of S(+)-Amphetamine (dextro-Amphetamine) solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material; R(-)-Amphetamine (levo-Amphetamine), 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material

SPE retention mechanism in this case is based on the electrostatic attraction of charged functional groups of the analyte(s) to oppositely charged functional groups on the sorbent.

SPE retention mechanism in this case is based on the electrostatic attraction of charged functional groups of the analyte(s) to oppositely charged functional groups on the sorbent.

條款

Optimized sample prep and chiral chromatography methods for the LC/MS analysis of these drug enantiomers in urine

In this study, optimized methods are presented for sample preparation and chiral chromatography for the LC/MS analysis of amphetamine and methamphetamine enantiomers in urine.

LC/MS Analysis of Methamphetamine Enantiomers on Astec® CHIROBIOTIC® V2 in Urine after SPE using Supel™-Select SCX

Retention occurs through polar interaction between the sorbent and analytes. Typical sample matrices that can be employed in normal-phase SPE include hydrocarbon or fatty oils diluted in a solvent like hexane, isooctane, chlorinated solvent, THF, diethyl ether, or ethyl acetate.

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務