推薦產品
產品名稱
Ascentis® Express C18, 2 μm UHPLC 色谱柱, 2 μm particle size, L × I.D. 15 cm × 2.1 mm
材料
stainless steel column
agency
suitable for USP L1
產品線
Ascentis®
特點
endcapped
製造商/商標名
Ascentis®
包裝
1 ea of
參數
1000 bar max. pressure (14500 psi)
60 °C temp. range
技術
HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
長度 × 內徑
15 cm × 2.1 mm
表面積
120 m2/g
雜質
<5 ppm metals
基質
Fused-Core particle platform
superficially porous particle
基質活性組
C18 (octadecyl) phase
粒徑
2 μm
孔徑
90 Å pore size
工作pH值
2-9
應用
food and beverages
分離技術
reversed phase
尋找類似的產品? 前往 產品比較指南
法律資訊
Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany
從最近期的版本中選擇一個:
分析證明 (COA)
Lot/Batch Number
Silvia Jakabová et al.
Journal of chromatography. A, 1232, 295-301 (2012-03-07)
Hyoscyamine (atropine) and scopolamine are the predominant tropane alkaloids in the Datura genus, occurring in all plant organs. The assessment of the alkaloid content of various plant parts is essential from the viewpoint of medical use, but also as a
Judy Stone
Methods in molecular biology (Clifton, N.J.), 1378, 301-320 (2015-11-26)
Serum from bar-coded tubes, and then internal standard, are pipetted to 96-well plates with an 8-channel automated liquid handler (ALH). The first precipitation reagent (methanol:ZnSO4) is added and mixed with the 8-channel ALH. A second protein precipitating agent, 1 %
Babu Rao Chandu et al.
SpringerPlus, 2(1), 194-194 (2013-06-07)
A bioequivalence study was proved of generic Febuxostat 80 mg tablets (T) in healthy volunteers.For this purpose, Authors developed a simple, sensitive, selective, rapid, rugged and reproducible liquid chromatography-tandem mass spectrometry method for the quantification of Febuxostat (FB) in human
Petra Šilarová et al.
Food chemistry, 237, 471-480 (2017-08-03)
The degradation of catechins and other phenolics in green tea infusions were monitored using fast HPLC/MS separation. The final separation was performed within 2.5min using Ascentis Express C18 column (50mm×2.1mm i.d.) packed with 2μm porous shell particles. Degradation was studied
Pankaj Partani et al.
Journal of chromatographic science, 54(8), 1385-1396 (2016-05-27)
A liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous determination of simvastatin (SV) and simvastatin acid (SVA) in human plasma. To improve assay sensitivity and achieve simultaneous analysis, SVA monitored in (-)ESI (electrospray ionization) mode within
條款
HPLC separation of 17 important cannabinoids including CBD, delta 9 THC and THCA. Read the application note
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務