推薦產品
等級
analytical standard
CofA
current certificate can be downloaded
包裝
ampule of 1 mL
濃度
50 μg/mL in hexane
技術
HPLC: suitable
gas chromatography (GC): suitable
格式
multi-component solution
儲存溫度
2-8°C
一般說明
Omegawax column test mix is used to assess the performance of an Omegawax capillary column in the analysis of fatty acid methyl esters.
應用
Omegawax column test mix has been used as an standard in studying the effect of supplementation with procyanidins obtained from Vitis vinifera seeds on certain selected markers of oxidative stress, via the analysis of fatty acid composition of phospholipids of red blood cell membrane using gas chromatography method of analysis (GC).
法律資訊
訊號詞
Danger
危險分類
Aquatic Chronic 2 - Asp. Tox. 1 - Flam. Liq. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 1 Inhalation - STOT SE 3
標靶器官
Central nervous system, Nervous system
儲存類別代碼
3 - Flammable liquids
水污染物質分類(WGK)
WGK 3
閃點(°F)
-7.6 °F - closed cup
閃點(°C)
-22 °C - closed cup
客戶也查看了
Procyanidins from Vitis vinifera seeds: in vivo effects on oxidative stress
Journal of Agricultural and Food Chemistry, 50, 6217-6221 (2002)
Comparison of two gas-liquid chromatograph columns for the analysis of fatty acids in ruminant meat.
Journal of chromatography. A, 1216(26), 5130-5139 (2009-05-19)
Two gas-liquid chromatograph capillary columns for the analysis of fatty acids (FA) in ruminant fat are compared. Those columns are the CP-Sil 88 of 100 m long with a highly polar stationary phase and the Omegawax 250 of 30 m
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 770(1-2), 91-99 (2002-05-16)
Four capillary columns (A: CP-WAX 52 CB 25 m x 0.25 mm; B: CP WAX 52 CB 30 m x 0.25 mm; C: CP-WAX 58 CB 25 m x 0.25 mm, Chrompack; D: OMEGAWAX 320 30 m x 0.32 mm
Analytical chemistry, 71(19), 4237-4244 (1999-10-12)
The technique of automated in-tube solid-phase microextraction (SPME) coupled with liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) was evaluated for the determination of beta-blockers in urine and serum samples. In-tube SPME is an extraction technique for organic compounds in aqueous samples
Journal of chromatography. B, Biomedical sciences and applications, 731(2), 353-359 (1999-10-08)
The technique of automated in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) was evaluated for the determination of ranitidine. In-tube SPME is an extraction technique for organic compounds in aqueous samples, in which analytes are extracted
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務