跳轉至內容
Merck
全部照片(1)

重要文件

13734-U

Supelco

Metal Packed GC Column (fits PerkinElmer®)

phase 3% SP-1500, matrix 80/120 Carbopack B support, L × O.D. × I.D. 10.0 ft (3.0 m) × 1/8 in. × 2.1 mm

登入查看組織和合約定價


About This Item

分類程式碼代碼:
41115710
NACRES:
SB.54

材料

stainless steel column

品質等級

製造商/商標名

PerkinElmer

參數

0-230 °C temperature (isothermal or programmed)

技術

gas chromatography (GC): suitable

長度 × 外徑 × 內徑

10.0 ft (3.0 m) × 1/8 in. × 2.1 mm

基質

80/120 Carbopack B support

基質活性組

3% SP-1500 phase

柱類型

packed GC

相容性

for use with PerkinElmer

尋找類似的產品? 前往 產品比較指南

一般說明

An economical metal column should be used for less demanding applications where the inertness of glass is not required. This column fits PerkinElmer 8000, 9000, AutoSystem, XL, and Clarus 500 (Not On-Column Injection).
Packed column percolates the carrier gas through the porous bed. In a packed column, separation is achieved by moving the solutes apart. Packed columns are made up of two main materials; stainless steel and Pyrex glass. Metal packed columns are more suitable for long and high carrier gas flow rates to tolerate the elevated pressures. Carbopack B, better known as graphitized carbon black has nonporous, nonpolar and homogeneous surface. This adsorbent is suitable as stationary phase in both packed and capillary columns. Carbopack B cartridges are more efficient than C-18 for extracting phenols.

應用

Carbopack B packed stainless steel column was used to measure chloroform, dichloromethane and methane of headspace samples using GC analysis.

法律資訊

PerkinElmer is a registered trademark of PerkinElmer Inc.

儲存類別代碼

11 - Combustible Solids

水污染物質分類(WGK)

WGK 2

閃點(°F)

Not applicable

閃點(°C)

Not applicable


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如果您需要協助,請聯絡 客戶支援

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

D M Bagley et al.
Applied and environmental microbiology, 61(9), 3195-3201 (1995-09-01)
The effects of methanol addition and consumption on chloroform degradation rate and product distribution in methanogenic methanol enrichment cultures and in cultures of Methanosarcina barkeri 227 were investigated. Degradation of chloroform with initial concentrations up to 27.3 microM in enrichment
A Di Corcia et al.
Analytical chemistry, 63(6), 580-585 (1991-03-15)
A general liquid-solid extraction procedure for the isolation of pesticides from groundwater and drinking water for high-performance liquid chromatography (HPLC) is presented. This simple and rapid procedure involved passing a 2-L sample through a 250-mg graphitized carbon black (Carbopack B)
Raymond P. W. Scott
Introduction to Analytical Gas Chromatography (1997)

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務