跳轉至內容
Merck
全部照片(4)

重要文件

M7256

Sigma-Aldrich

N,N′-亚甲基双丙烯酰胺

suitable for electrophoresis (after filtration or allowing insolubles to settle)

同義詞:

BIS

登入查看組織和合約定價


About This Item

線性公式:
(CH2=CHCONH)2CH2
CAS號碼:
分子量::
154.17
Beilstein:
1706297
EC號碼:
MDL號碼:
分類程式碼代碼:
41105319
PubChem物質ID:
NACRES:
NB.22

形狀

powder

品質等級

技術

electrophoresis: suitable

適合性

suitable for electrophoresis (after filtration or allowing insolubles to settle)

SMILES 字串

C=CC(=O)NCNC(=O)C=C

InChI

1S/C7H10N2O2/c1-3-6(10)8-5-9-7(11)4-2/h3-4H,1-2,5H2,(H,8,10)(H,9,11)

InChI 密鑰

ZIUHHBKFKCYYJD-UHFFFAOYSA-N

尋找類似的產品? 前往 產品比較指南

應用

与丙烯酰胺混合以制备聚丙烯酰胺凝胶,用于蛋白质和核酸电泳。

其他說明

交联剂,用于制备聚丙烯酰胺(来自01698特纯级丙烯酰胺),用作电泳中的凝胶,以分离、分析和表征核酸、蛋白和其他带电物质;A.H. Gordon,聚丙烯酰胺和淀粉凝胶中的蛋白电泳Vol. 1,第I部分,”生物化学及分子生物学中的实验室技术“

象形圖

Skull and crossbonesHealth hazard

訊號詞

Danger

危險分類

Acute Tox. 3 Oral - Acute Tox. 4 Dermal - Carc. 1B - Muta. 1B - Repr. 2 - STOT RE 1 Oral

標靶器官

Peripheral nervous system

儲存類別代碼

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable

個人防護裝備

dust mask type N95 (US), Eyeshields, Faceshields, Gloves


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

未看到正確版本?

如果您需要一個特定的版本,您可以透過批號來尋找特定憑證。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

D. Rickwood, B.D. Hames
Gel Electrophoresis of Nucleic Acids: A Practical Approach (1983)
A Bringard et al.
Electrophoresis, 11(10), 802-809 (1990-10-01)
The principle and some applications of multiphasic electrophoresis with diversified spacers are described. The method combines previously published concepts of introducing highly diversified spacers into the stack of an isotachophoretic system with the theory of snow- and telescope-electrophoresis. The link
A J Aho et al.
British journal of anaesthesia, 115(2), 258-266 (2015-07-04)
Concomitantly recorded Bispectral Index® (BIS) and Entropy™ values sometimes show discordant trends during general anaesthesia. Previously, no attempt had been made to discover which EEG characteristics cause discrepancies between BIS and Entropy. We compared BIS and Entropy values, and analysed
Bjørn Bjorvatn et al.
Sleep & breathing = Schlaf & Atmung, 19(4), 1387-1393 (2015-04-10)
The objective of the present study was to investigate the prevalence of insomnia and excessive sleepiness in relation to the presence and severity of obstructive sleep apnea (OSA). The sample consisted of patients referred to a university hospital on suspicion
Jean Guglielminotti et al.
Anesthesiology, 122(5), 985-993 (2015-03-03)
Individual assessment of the amplitude of a physiologic reflex evoked by a standardized noxious test (SNT) before surgical stimulation has been suggested to predict movement upon the forthcoming surgical stimulation. This study aimed to compare the ability of pupillary dilatation

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務