推薦產品
等級
BioPerformance Certified
化驗
≥99.0%
形狀
crystalline
技術
cell culture | mammalian: suitable
雜質
endotoxin and bioburden, tested
pH值
2.5-5.0 (25 °C, 213.3 g/L)
有用的pH值範圍
6.4-7.8
pKa (25 °C)
7.1
溶解度
water: 0.5 g/mL, clear, colorless
應用
diagnostic assay manufacturing
異物活動
DNAse (exonuclease), NICKase (endonuclease), RNAse, and protease, none detected
儲存溫度
room temp
SMILES 字串
OCCN(CCO)CCS(O)(=O)=O
InChI
1S/C6H15NO5S/c8-4-1-7(2-5-9)3-6-13(10,11)12/h8-9H,1-6H2,(H,10,11,12)
InChI 密鑰
AJTVSSFTXWNIRG-UHFFFAOYSA-N
尋找類似的產品? 前往 產品比較指南
一般說明
N-N-双(2-羟乙基)-2-氨基乙磺酸(BES)是一种两性离子缓冲液,常用于生物化学和分子生物学研究中。BES缓冲液可用作二级pH标准物质,能使溶液保持在稳定的pH范围内,特别是在6.2-7.6范围内。一项研究表明,在细菌内毒素检查中使用这种缓冲液可以最大限度地减少干扰因素的影响。BES还可用作磷酸钙介导质粒DNA转染真核细胞的缓冲溶液。
應用
BES缓冲液可用于:
- 作为体外分析胸腺细胞凋亡时培养胸腺细胞用的opti-minimal essential medium(MEM)培养基的补充剂
- 作为腺相关病毒(AAV)载体制备、提取和纯化用的硼酸盐缓冲液(BBS)的组分
- 作为精液采集和冷冻保存用的稀释剂之一的组分
儲存類別代碼
11 - Combustible Solids
水污染物質分類(WGK)
WGK 3
閃點(°F)
Not applicable
閃點(°C)
Not applicable
個人防護裝備
dust mask type N95 (US), Eyeshields, Gloves
客戶也查看了
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 10(12), 1449-1455 (2014-11-26)
Stent fracture is important because it may cause adverse events. The interventional cardiologist needs independent data to aid stent selection. Stent designers need data to improve stent design. We used a repetitive bend test to compare durability and fracture for
Circulation journal : official journal of the Japanese Circulation Society, 79(6), 1323-1331 (2015-04-07)
Coronary adventitia harbors a wide variety of components, such as inflammatory cells and vasa vasorum (VV). Adventitial VV initiates the development of coronary artery diseases as an outside-in supply route of inflammation. We have recently demonstrated that drug-eluting stent implantation
The journal of physical chemistry letters, 6(15), 2933-2937 (2015-08-13)
Colloidal CdSe quantum dot (QD) core ensembles were photodimmed and allowed to recover in the dark using ambient thermal energy at a range of temperatures. Nonlinear thermal recovery is well described by a stretched exponential function, and further analysis yields
Nano letters, 15(7), 4657-4663 (2015-06-24)
Noncrystalline semiconductor materials often exhibit hysteresis in charge transport measurements whose mechanism is largely unknown. Here we study the dynamics of charge injection and transport in PbS quantum dot (QD) monolayers in a field effect transistor (FET). Using Kelvin probe
International journal of cardiology, 186, 178-185 (2015-04-02)
Numerous studies have demonstrated an association between endothelial shear stress (ESS) and neointimal formation after stent implantation. However, the role of ESS on the composition of neointima and underlying plaque remains unclear. Patients recruited in the Comfortable AMI-IBIS 4 study
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.