推薦產品
等級
analytical standard
儲存期限
limited shelf life, expiry date on the label
製造商/商標名
H&D Fitzgerald Ltd.
應用
cleaning products
cosmetics
environmental
flavors and fragrances
food and beverages
industrial qc
personal care
petroleum
pharmaceutical (small molecule)
形式
mixture
SMILES 字串
[Na+].[Br-]
InChI
1S/BrH.Na/h1H;/q;+1/p-1
InChI 密鑰
JHJLBTNAGRQEKS-UHFFFAOYSA-M
尋找類似的產品? 前往 產品比較指南
應用
This density CRM is used for the calibration of all types of laboratory density meters in the test temperature range of 15 to 25 °C.
特點和優勢
- Manufactured and verified in an ISO 17025 accredited laboratory, as per UKAS
- Carries an associated uncertainty of +/- 0.010 Kg/m3
- Provided in a sealed glass ampoule of 10 mL to assure safe delivery
- Accompanied with a certificate of analysis (CoA) having information on the expiry date for an effective audit
訊號詞
Warning
危險聲明
危險分類
Repr. 2 - STOT RE 2 - STOT SE 3
標靶器官
Central nervous system
儲存類別代碼
12 - Non Combustible Liquids
水污染物質分類(WGK)
WGK 1
閃點(°F)
Not applicable
閃點(°C)
Not applicable
客戶也查看了
Kelei Zhuo et al.
The journal of physical chemistry. B, 116(33), 10026-10035 (2012-07-12)
Dilution enthalpies and mixing enthalpies of sodium halide and some saccharides (glucose, galactose, xylose, arabinose, fructose, and sucrose) in aqueous solution were determined by calorimetric measurements at 298.15 K. The values were used to determine enthalpic pair interaction parameters. Combined
V Prigiobbe et al.
Water science and technology : a journal of the International Association on Water Pollution Research, 64(1), 132-138 (2011-11-08)
Water authorities interested in the evaluation of the structural state of a sewer must quantify leakage to plan strategic intervention. However, the quantification of the exfiltration and the localisation of structural damage are challenging tasks that usually require expensive and
Xiuquan Sun et al.
The journal of physical chemistry. A, 115(23), 5767-5773 (2010-10-14)
Molecular dynamic simulations with polarizable potentials were performed to systematically investigate the distribution of NaCl, NaBr, NaI, and SrCl(2) at the air/liquid methanol interface. The density profiles indicated that there is no substantial enhancement of anions at the interface for
Feng Jiang et al.
Nephrology (Carlton, Vic.), 15(4), 476-479 (2010-07-09)
For years, bioelectrical impedance analysis has been widely used to evaluate the hydration status in dialysis patients. However, its value in assessment and controlling the hydration status in non-dialysis patients with kidney disease, such as nephrotic syndrome, is little mentioned.
Kajari Maiti et al.
The journal of physical chemistry. B, 114(22), 7499-7508 (2010-05-19)
Bolaforms B(1), B(2), and B(3) of the formulas, Br(-)Me(3)N(+)(CH(2))(10)N(+)Me(3)Br(-), Br(-)Me(3)N(+)(CH(2))(10)OH, and Br(-)Me(3)N(+)(CH(2))(10)COO(-)Na(+), respectively, were synthesized, and their properties in the bulk as well as at the air/aqueous NaBr (10 mM) solution interface have been studied. Their interactions with sodium dodecyl
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務