推薦產品
等級
analytical standard
儲存期限
limited shelf life, expiry date on the label
濃度
50 μg/mL in isooctane
技術
HPLC: suitable
gas chromatography (GC): suitable
應用
environmental
格式
single component solution
儲存溫度
2-8°C
SMILES 字串
Brc1cc(Br)c(Oc2ccc(Br)c(Br)c2)c(Br)c1
InChI
1S/C12H5Br5O/c13-6-3-10(16)12(11(17)4-6)18-7-1-2-8(14)9(15)5-7/h1-5H
InChI 密鑰
KXEOYBYEJCRPGB-UHFFFAOYSA-N
一般說明
BDE No 119 is an persistent environmental contaminant with low acute toxicity, belonging to the class of polybrominated diphenyl ethers. It can find wide applications as additive flame-retardants in consumer products ranging from textiles to polymers.
應用
BDE No 119 may be used as an analytical reference standard to determine the analyte in river sediments using gas chromatography coupled to mass spectrometry (GC-MS) and selective pressurized liquid extraction followed by gas chromatography coupled to negative ion chemical ionization-mass spectrometry (GC-NCI-MS).
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
其他說明
The customer needs to make sure that the standard is homogeneous, this can be achieved by shaking, vortexing , or sonicating the ampoule before opening the ampoule. Care should be taken when opening the ampoule to avoid any injuries from the broken glass.
The standard should be transferred to a clean and appropriate vial or flask using clean pipettes or micro pipettes. The vial should be immediately capped to avoid any loss or evaporation of the solvent.
After opening the ampoule, the standard should not be stored or kept in the ampoule. To preserve the integrity of the product, the standard should be transferred to an appropriate vial that must be capped and stored according to the recommendation on the Certificate of Analysis.
The standard should be transferred to a clean and appropriate vial or flask using clean pipettes or micro pipettes. The vial should be immediately capped to avoid any loss or evaporation of the solvent.
After opening the ampoule, the standard should not be stored or kept in the ampoule. To preserve the integrity of the product, the standard should be transferred to an appropriate vial that must be capped and stored according to the recommendation on the Certificate of Analysis.
訊號詞
Danger
危險分類
Aquatic Acute 1 - Aquatic Chronic 1 - Asp. Tox. 1 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3
標靶器官
Central nervous system
儲存類別代碼
3 - Flammable liquids
水污染物質分類(WGK)
WGK 2
閃點(°F)
10.4 °F - closed cup
閃點(°C)
-12 °C - closed cup
個人防護裝備
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
Determination of potential sources of PCBs and PBDEs in sediments of the Niagara River.
Environmental Pollution (Barking, Essex : 1987), 139(2), 489-497 (2006)
Determination of decabromodiphenyl ether in sediments using selective pressurized liquid extraction followed by GC-NCI-MS.
Analytical and Bioanalytical Chemistry, 378(3), 610-614 (2004)
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務