跳轉至內容
Merck
全部照片(1)

重要文件

333417

Sigma-Aldrich

里格罗因

reagent grade

同義詞:

石油精, 矿油精

登入查看組織和合約定價


About This Item

CAS號碼:
EC號碼:
MDL號碼:
分類程式碼代碼:
12190000
bp:
60-80 °C (lit.)

等級

reagent grade

蒸汽密度

>1 (vs air)

蒸汽壓力

25.8 psi

形狀

liquid

expl. lim.

8 %

dilution

(for analytical testing)

折射率

n20/D 1.376 (lit.)

bp

60-80 °C (lit.)

密度

0.656 g/mL at 25 °C (lit.)

InChI

1S/C7H7.BrH.Mg/c1-7-5-3-2-4-6-7;;/h3-6H,1H3;1H;/q;;+1/p-1

InChI 密鑰

ZRJNGFJIBZKXTP-UHFFFAOYSA-M

尋找類似的產品? 前往 產品比較指南

其他說明

-D后缀仅用于管理目的。
所有-D包装与之前的无-D包装均具有100%相同的产品、相同的质量、相同的规格

象形圖

FlameHealth hazard

訊號詞

Danger

危險分類

Asp. Tox. 1 - Carc. 1B - Flam. Liq. 2 - Muta. 1B

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 3

閃點(°F)

-56.2 °F - closed cup

閃點(°C)

-49 °C - closed cup

個人防護裝備

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

未看到正確版本?

如果您需要一個特定的版本,您可以透過批號來尋找特定憑證。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

客戶也查看了

S Dauger et al.
Archives de pediatrie : organe officiel de la Societe francaise de pediatrie, 10(3), 221-223 (2003-06-28)
The Authors report a case of acute White-Spirit poisoning with pulmonary hypertension associated to respiratory distress syndrome. A 14-month-old infant drank an unknown quantity of White-Spirit while his parents were painting. After he spontaneously vomited, he presented a seizure at
Lena Ernstgård et al.
Journal of applied toxicology : JAT, 29(3), 255-262 (2008-12-17)
A move from 'standard' white spirit (stdWS, 15-20% aromatics) to low-aromatic or dearomatized white spirit (deWS) has been seen, as the latter are considered to carry a smaller risk of health effects. However, data on health risks of deWS on
Gunnar Damgård Nielsen et al.
Basic & clinical pharmacology & toxicology, 98(2), 115-123 (2006-02-01)
Numerous studies have suggested that long-term occupational exposure to white spirit may cause chronic toxic encephalopathy (WHO 1996). This review summarizes the chronic nervous system effects of white spirit in animal studies during a 30-year period. First, routine histopathology was
P S Tofts et al.
Magnetic resonance imaging, 15(1), 69-75 (1997-01-01)
The selection of a suitable low dielectric constant liquid for radiofrequency coil nonuniformity measurements is described. Measurements of dielectric constant (relative permittivity) were made on a range of candidate liquids. After excluding liquids that were too inflammable or too viscous
Wan N S Mat-Desa et al.
Analytical chemistry, 83(20), 7745-7754 (2011-09-17)
Three different medium petroleum distillate (MPD) products (white spirit, paint brush cleaner, and lamp oil) were purchased from commercial stores in Glasgow, Scotland. Samples of 10, 25, 50, 75, 90, and 95% evaporated product were prepared, resulting in 56 samples

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務