全部照片(2)
About This Item
經驗公式(希爾表示法):
C18D3H17FN3O4
CAS號碼:
分子量::
364.39
MDL號碼:
分類程式碼代碼:
41116107
PubChem物質ID:
NACRES:
NA.24
推薦產品
等級
analytical standard
品質等級
產品線
VETRANAL®
儲存期限
limited shelf life, expiry date on the label
技術
HPLC: suitable
gas chromatography (GC): suitable
應用
forensics and toxicology
pharmaceutical (small molecule)
veterinary
形式
neat
質量偏移
M+3
SMILES 字串
[2H]C([2H])([2H])N1CCN(CC1)c2c(F)cc3C(=O)C(=CN4C(C)COc2c34)C(O)=O
InChI
1S/C18H20FN3O4/c1-10-9-26-17-14-11(16(23)12(18(24)25)8-22(10)14)7-13(19)15(17)21-5-3-20(2)4-6-21/h7-8,10H,3-6,9H2,1-2H3,(H,24,25)/i2D3
InChI 密鑰
GSDSWSVVBLHKDQ-BMSJAHLVSA-N
一般說明
Ofloxacin-d3 is a deuterated labeled compound typically used as an analytical standard in chromatography applications.
應用
Ofloxacin-d3 may be used as an analytical standard for the determination of ofloxacin in:
- Hospital wastewater samples by ultra-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI-MS/MS) with multiple reaction monitoring (MRM) detection.
- Raw bovine milk and commercial skimmed milk samples as well as bottled natural mineral waters by solid phase extraction (SPE) and LC-ESI-MS/MS operating in (MRM) mode of detection.
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
法律資訊
VETRANAL is a registered trademark of Merck KGaA, Darmstadt, Germany
儲存類別代碼
11 - Combustible Solids
水污染物質分類(WGK)
WGK 3
閃點(°F)
Not applicable
閃點(°C)
Not applicable
Rapid residue analysis of fluoroquinolones in raw bovine milk by online solid phase extraction followed by liquid chromatography coupled to tandem mass spectrometry.
Kantiani L, et al.
Journal of Chromatography A, 1218(50), 9019-9027 (2011)
Factors influencing the extraction of pharmaceuticals from sewage sludge and soil: an experimental design approach.
Ferhi S, et al.
Analytical and Bioanalytical Chemistry, 408(22), 6153-6168 (2016)
Analysis of multiclass antibiotic residues in urban wastewater in Tunisia.
Harrabi M, et al.
Environmental Nanotechnology, Monitoring & Management, 10(22), 163-170 (2018)
Diana Nara Ribeiro de Sousa et al.
Chemosphere, 205, 137-146 (2018-04-25)
The performances of two FAU-type zeolites with different SiO2/Al2O3 ratios were evaluated for the removal of antibiotics of three different classes, namely azithromycin, ofloxacin, and sulfamethoxazole, from aqueous solutions. Commercial zeolites were used, without any previous treatment. Use of a
Calibration and field evaluation of polar organic chemical integrative sampler (POCIS) for monitoring pharmaceuticals in hospital wastewater.
Bailly E, et al.
Environmental Pollution (Barking, Essex : 1987), 174(22), 100-105 (2013)
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務