推薦產品
品質等級
等級
analytical standard
化驗
99.999%
技術
mass spectrometry (MS): suitable
mp
626 °C (lit.)
密度
4.51 g/mL at 25 °C (lit.)
應用
cleaning products
cosmetics
flavors and fragrances
food and beverages
personal care
形式
neat
SMILES 字串
[I-].[Cs+]
InChI
1S/Cs.HI/h;1H/q+1;/p-1
InChI 密鑰
XQPRBTXUXXVTKB-UHFFFAOYSA-M
尋找類似的產品? 前往 產品比較指南
一般說明
碘化铯是一种简单的离子盐。它具有在低压下从立方 B2 结构到体心四方结构的二顺序变换能力。多用作 X 射线影像增强器的输入屏。
應用
在非变性电喷雾电离飞行时间质谱 (ESI-TOF MS) 分析过程中,使用碘化铯作为校准标准品,用于测定蛋白质聚集体中的蛋白质样品。
适合作为电喷雾电离 MS (ESI) 的标准品
特點和優勢
常用于医疗成像荧光屏、闪烁体、热量计和各种粒子探测器等设备。
訊號詞
Warning
危險聲明
危險分類
Aquatic Acute 1 - Repr. 2
儲存類別代碼
13 - Non Combustible Solids
水污染物質分類(WGK)
WGK 2
閃點(°F)
Not applicable
閃點(°C)
Not applicable
個人防護裝備
dust mask type N95 (US), Eyeshields, Faceshields, Gloves
客戶也查看了
J.F. Anacleto et al.
Org. Mass Spectrom., 27, 660-660 (1992)
E Knittle et al.
Science (New York, N.Y.), 223(4631), 53-56 (1984-01-06)
Cesium iodide, a simple ionic salt at low pressures, undergoes a second-order transformation at 40 gigapascals (400 kilobars) from the cubic B2 (cesium chloride-type) structure to the body-centered tetragonal structure. Also, the energy gap between valence and conduction bands decreases
Başak Kükrer et al.
Pharmaceutical research, 27(10), 2197-2204 (2010-08-04)
The aim of this study was to develop a method to characterize intact soluble monoclonal IgG1 antibody (IgG) oligomers by mass spectrometry. IgG aggregates (dimers, trimers, tetramers and high-molecular-weight oligomers) were created by subjecting an IgG formulation to several pH
Wei Zhao et al.
Medical physics, 31(9), 2594-2605 (2004-10-19)
Columnar structured cesium iodide (CsI) scintillators doped with Thallium (Tl) have been used extensively for indirect x-ray imaging detectors. The purpose of this paper is to develop a methodology for systematic investigation of the inherent imaging performance of CsI as
P Thibault et al.
Rapid communications in mass spectrometry : RCM, 5(10), 484-490 (1991-10-01)
The direct coupling of capillary electrophoresis (CE) and mass spectrometry, combined with ionspray ionization using a coaxial capillary arrangement, is described. The CE/mass spectrometer interface is shown to be effective for the analysis of native and tryptic peptides and of
文章
MALDI-TOF MS is a tool for confirming end group identity & transformations, verifying successful & complete conjugation. Functionalized polymers enable a quick & efficient route for synthesis of various polymer conjugates for many applications if apt end group is present.
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務