跳轉至內容
Merck
全部照片(2)

重要文件

RLI1MAG-92K

Millipore

MILLIPLEX® Rat Liver Injury Panel - Toxicity Multiplex Assay

同義詞:

Luminex® Rat Liver Toxicity Assay, Millipore Rat Liver Toxicity Assay, Rat Liver Injury Multiplex Panel

登入查看組織和合約定價


About This Item

分類程式碼代碼:
12161503
eCl@ss:
32161000
NACRES:
NA.84

描述

The analytes available for this multiplex kit are: Liver-type arginase 1 (ARG1), aspartate transaminase 1 (GOT1), α-glutathianone S-transferase (GSTα), sorbitol dehydrogenase (SDH), and 5′-Nucleotidase (5′-NT/CD73).

品質等級

物種活性

rat

製造商/商標名

Milliplex®

assay range

accuracy: 77-92%
sensitivity: 0.021-4.038 ng/mL
(MinDC+2SD)

standard curve range: 0.02-15.0 ng/mL
(GSTα)

standard curve range: 0.04-30.0 ng/mL
(5′-NT/CD73)

standard curve range: 0.08-60.0 ng/mL
(GOT1)

standard curve range: 0.10-75.0 ng/mL
(ARG1)

standard curve range: 0.62-450.0 ng/mL
(SDH)

技術

multiplexing: suitable

檢測方法

fluorometric (Luminex xMAP)

運輸包裝

wet ice

一般說明

The MILLIPLEX® Rat Liver Injury Bead Panel (RLI1MAG-92K) contains all the components necessary to simultaneous quantify the following 5 analytes in serum and plasma samples: Liver-Type Arginase 1 (ARG1)*, Aspartate transaminase 1 (GOT1), α-glutathione S-transferase (GSTα)*, Sorbitol Dehydrogenase (SDH)*, 5′-Nucleotidase/CD73 (5′-NT).

*ARG1, GSTα, and SDH are biomarkers listed in the Predictive Safety Testing Consortium (PSTC) project pipeline which have a strong translational role in drug safety testing.

The MILLIPLEX® portfolio provides a valuable research assay to investigate multiple biomarkers of liver injury in rat serum and plasma samples using the Luminex® xMAP® instrument platform. This kit uses a 96-well format, contains a lyophilized standard cocktail, two quality controls and can measure up to 38 serum or plasma samples in duplicate.

Drug toxicity is the leading cause of acute liver failure in the United States. Patients with liver damage generally display elevated amounts of specific liver proteins in serum; these proteins can serve as biomarkers of drug-related liver toxicity. Monitoring these biomarkers can greatly help clinicians avoid drug-induced liver failure. Performing laboratory tests to characterize the side effects of potential therapeutics is an essential part of drug development. The rat is a leading animal model for these pre-clinical toxicity studies. The search for sensitive, organ-specific toxicity biomarkers is complemented by the development of novel assays to measure these critical analytes. Liver-Type Arginase 1 (ARG1), α-glutathione S-transferase (GSTα), and Sorbitol Dehydrogenase (SDH) are biomarkers listed in the Predictive Safety Testing Consortium (PSTC) project pipeline which have a strong translational role in drug safety testing. Aspartate transaminase 1 (GOT1) and 5′-Nucleotidase / CD73 (5′-NT) are traditional biomarkers recognized by both the Food and Drug Administration (FDA) and its European counterpart, the European Medicines Agency (EMA).

Panel Type: Toxicity

應用

  • Analytes: 5′-Nucleotidase (5′-NT/CD73), Liver-Type Arginase 1 (ARG1), Aspartate transaminase 1 (GOT1), α-Glutathione S-Transferase (GSTα), Sorbitol Dehydrogenase (SDH)
  • Recommended Sample Type: Rat serum and plasma
  • Recommended Sample Dilution: 25 μL per well of 1:25 diluted serum or plasma
  • Assay Run Time: 2 hours at room temperature (20-25°C)
  • Research Category: Toxicity

特點和優勢

Design your multiplex kit by choosing available analytes within this panel.

成分

Rat Liver Injury Standard, 1 vial, lyophilized

Rat Liver Injury Quality Control 1, 1 vial, lyophilized

Rat Liver Injury Quality Control 2, 1 vial, lyophilized

Assay Buffer, 1 bottle, 30 mL

Wash Buffer, 10X (0.05% Proclin), 2 bottles, 30 mL ea

Rat Liver Injury Detection Antibodies, 1 bottle, 3.2 mL

Streptavidin-Phycoerythrin, 1 bottle, 3.2 mL

Mixing Bottle, 1 bottle

Sample Plate, 96 well format, 1 plate

2 Foil Plate Sealers

其他說明

Please contact Technical Service for linearity of dilution.
Sensitivity: Please see kit protocol for individual assay sensitivities.

法律資訊

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

象形圖

Skull and crossbonesEnvironment

訊號詞

Danger

危險分類

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Sens. 1

儲存類別代碼

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects


分析證明 (COA)

輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

相關內容

See how multiplex assays, such as the Luminex® bead-based multiplex immunoassay MILLIPLEX® Rat Liver Injury Panel, enable researchers to simultaneously measure multiple hepatotoxic biomarkers and cytokines to expand knowledge on drug-induced liver injury processes.

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務