推薦產品
品質等級
物種活性
human
製造商/商標名
Milliplex®
assay range
accuracy: 79-108%
standard curve range: 0.18-750 pg/mL
(IL-6)
standard curve range: 0.24-1,000 pg/mL
(IL-13)
standard curve range: 0.24-1,000 pg/mL
(IL-21)
standard curve range: 0.31-1,250 pg/mL
(IL-8)
standard curve range: 0.31-1,250 pg/mL
(MIP-1α)
standard curve range: 0.37-1,500 pg/mL
(IL-7)
standard curve range: 0.43-1,750 pg/mL
(TNFα)
standard curve range: 0.49-2,000 pg/mL
(IL-1β)
standard curve range: 0.49-2,000 pg/mL
(IL-12 (p70))
standard curve range: 0.49-2,000 pg/mL
(IL-2)
standard curve range: 0.49-2,000 pg/mL
(IL-5)
standard curve range: 0.61-2,500 pg/mL
(IFNγ)
standard curve range: 0.61-2,500 pg/mL
(MIP-3α)
standard curve range: 0.73-3,000 pg/mL
(IL-17A)
standard curve range: 0.92-3,750 pg/mL
(MIP-1β)
standard curve range: 1.22-5,000 pg/mL
(GM-CSF)
standard curve range: 1.46-6,000 pg/mL
(IL-10)
standard curve range: 1.46-6,000 pg/mL
(ITAC)
standard curve range: 1.83-7,500 pg/mL
(IL-4)
standard curve range: 18.3-75,000 pg/mL
(Fractalkine)
standard curve range: 7.93-32,500 pg/mL
(IL-23)
inter-assay cv: <20%
intra-assay cv: <10%
技術
multiplexing: suitable
相容性
configured for Premixed
檢測方法
fluorometric (Luminex xMAP)
運輸包裝
ambient
一般說明
Low levels of inflammation are involved in many clinical and sub-clinical disease states, such as autoimmune disease, cardiovascular disease, diabetes, neurological disorders, and cancer. Measuring picogram levels of cytokines, therefore, is critical for understanding the pathogenesis of these diseases.
The 384-well Human High Sensitivity T Cell Panel is the 384-well version of the current 96-well Human High Sensitivity T Cell Panel, and it exceeds expectations in terms of throughput, sensitivity and sample detectability.
The MILLIPLEX® 384-well Human High Sensitivity T Cell Premixed 21-Plex Panel is to be used for the simultaneous quantification of these analytes in serum, plasma, or tissue/cell culture supernatant: Fractalkine/CX3CL1, GM-CSF, IFN-γ, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-7, IL-8/CXCL8, IL-10, IL-12 (p70), IL-13, IL-17A/CTLA8, IL-21, IL-23, ITAC/EXCL11, MIP-1α/CCL3, MIP-1β/CCL4, MIP-3α/CCL20 and TNFα.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Cytokines/Chemokines
特異性
There is no detectable cross-reactivity within the panel.
應用
- Analytes: Fractalkine, GM-CSF, IFNγ, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-7, IL-8, IL-10, IL-12 (p70), IL-13, IL-17A, IL-21, IL-23, I-TAC, MIP-1α, MIP-1β, MIP-3α, TNF-α
- Because there are unique features concerning sample prep and assay set-up, please read the entire protocol before running the assay.
- Recommended Sample type: Serum, plasma or tissue/cell lysate and culture supernatant
- Assay Run Time: Overnight
- Research Category: Inflammation & Immunology
- Research Subcategory: Immune Response, Metabolic Disorders, Chronic Inflammatory Disease, Cardiovascular Disease, Neuroscience
儲存和穩定性
其他說明
法律資訊
免責聲明
訊號詞
Danger
危險分類
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
標靶器官
Respiratory Tract
儲存類別代碼
10 - Combustible liquids
分析證明 (COA)
輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。