HMHEMAG-34K
MILLIPLEX® 人代谢激素磁珠板 - 代谢多重检测
The Human Metabolic Hormone Panel, using the Luminex xMAP technology, enables the simultaneous analysis of 13 protein biomarkers in human serum, plasma and cell/tissue culture samples.
同義詞:
human metabolic hormone immunoassay panel, luminex human metabolic hormone multiplex assay, millipore human metabolism multiplex kit
About This Item
推薦產品
物種活性
human
製造商/商標名
Milliplex®
assay range
accuracy: 101%
(Glucagon)
accuracy: 102%
(Leptin)
accuracy: 103%
(GIP)
accuracy: 103%
(GLP-1 (Total))
accuracy: 105%
(Ghrelin (Active))
accuracy: 106%
(MCP-1)
accuracy: 97%
(TNFα)
accuracy: 99%
(C-Peptide)
sensitivity: 0.5 pg/mL
(MinDC+2SD; TNF?)
sensitivity: 1.1 pg/mL
(MinDC+2SD; GIP)
sensitivity: 13 pg/mL
(MinDC+2SD; IL-6)
sensitivity: 14 pg/mL
(MinDC+2SD; Ghrelin (Active))
sensitivity: 14 pg/mL
(MinDC+2SD; MCP-1)
sensitivity: 146 pg/mL
(MinDC+2SD; PYY)
sensitivity: 15 pg/mL
(MinDC+2SD; Amylin (Total))
sensitivity: 16 pg/mL
(MinDC+2SD; C-Peptide)
sensitivity: 16 pg/mL
(MinDC+2SD; Glucagon)
sensitivity: 160 pg/mL
(MinDC+2SD; Insulin)
sensitivity: 2.4 pg/mL
(MinDC+2SD; GLP-1 (Active))
sensitivity: 2.9 pg/mL
(MinDC+2SD; PP)
sensitivity: 28 pg/mL
(MinDC+2SD; Amylin (Active))
sensitivity: 64 pg/mL
(MinDC+2SD; Leptin)
sensitivity: 7.3 pg/mL
(MinDC+2SD; GLP-1 (Total))
standard curve range: 0.69-500 pg/mL
(TNFα)
standard curve range: 1.4-1,000 pg/mL
(GIP)
standard curve range: 13.7-10,000 pg/mL
(Amylin (Active))
standard curve range: 13.7-10,000 pg/mL
(Amylin (Total))
standard curve range: 13.7-10,000 pg/mL
(Ghrelin (Active))
standard curve range: 13.7-10,000 pg/mL
(Glucagon)
standard curve range: 13.7-10,000 pg/mL
(IL-6)
standard curve range: 13.7-10,000 pg/mL
(MCP-1)
standard curve range: 13.7-10,000 pg/mL
(PYY)
standard curve range: 137-100,000 pg/mL
(Insulin)
standard curve range: 137-100,000 pg/mL
(Leptin)
standard curve range: 2.7-2,000 pg/mL
(GLP-1 (Active))
standard curve range: 2.7-2,000 pg/mL
(GLP-1 (Total))
standard curve range: 2.7-2,000 pg/mL
(PP)
standard curve range: 27.4-20,000 pg/mL
(C-Peptide)
inter-assay cv: <15%
intra-assay cv: <10%
(C-Peptide)
inter-assay cv: <15%
intra-assay cv: <10%
(GIP)
inter-assay cv: <15%
intra-assay cv: <10%
(GLP-1 (Active))
inter-assay cv: <15%
intra-assay cv: <10%
(GLP-1 (Total))
inter-assay cv: <15%
intra-assay cv: <10%
(Ghrelin (Active))
inter-assay cv: <15%
intra-assay cv: <10%
(Glucagon)
inter-assay cv: <15%
intra-assay cv: <10%
(IL-6)
inter-assay cv: <15%
intra-assay cv: <10%
(Insulin)
inter-assay cv: <15%
intra-assay cv: <10%
(Leptin)
inter-assay cv: <15%
intra-assay cv: <10%
(MCP-1)
inter-assay cv: <15%
intra-assay cv: <10%
(PP)
inter-assay cv: <15%
intra-assay cv: <10%
(PYY)
inter-assay cv: <15%
intra-assay cv: <10%
(TNFα)
inter-assay cv: <20%
intra-assay cv: <10%
(Amylin (Active))
inter-assay cv: <20%
intra-assay cv: <10%
(Amylin (Total))
技術
multiplexing: suitable
檢測方法
fluorometric (Luminex xMAP)
運輸包裝
wet ice
一般說明
MILLIPLEX®人体代谢激素面板是一种15种分析物,13重试剂盒,用于同时定量血清、血浆和细胞/组织培养样品中以下分析物的任何或全部:胰淀素(活性)或胰淀素(总计),C肽,胃饥饿素(活性),GIP,GLP-1(活性)或GLP-1(总计),胰高血糖素,IL-6,胰岛素,瘦素,MCP-1,PP,PYY,TNFα。该试剂盒采用96孔板,包含冻干标准混合物、两个内部检测质控品,可最多可测定38份样本,重复两次。
Luminex® xMAP®平台使用磁珠免疫分析格式,以实现理想的速度和灵敏度,同时定量多种分析物,从而显著提高生产力,同时节省宝贵的样本量。
面板类型:代谢
應用
- 分析物:胰淀素(活性)或胰淀素(总计),C肽,胃饥饿素(活性),GIP(总计),GLP-1(活性)、GLP-1(总计),胰高血糖素,IL-6,胰岛素,瘦素,MCP-1(CCL2),胰多肽(PP),PYY(总计),TNF-α
- 注释:不能同时测定以下分析物:胰淀素(活性)& 胰淀素(总计);GLP-1(活性)& GLP-1(总计)。
- 推荐的样品类型:人血清、血浆和细胞/组织培养上清液或裂解液
- 推荐的样品稀释液:每孔25μ L未稀释的血清或血浆;细胞/组织培养样品可以未经稀释使用,也可以用适当的对照培养基稀释使用。注意:以下分析物需要向血清或血浆样品中添加蛋白酶抑制剂(详见方案中的样品采集和储存部分):GLP-1(DPPIV抑制剂);胰淀素(蛋白酶抑制剂混合物);胰高血糖素(抑肽酶);胃饥饿素(活性)(丝氨酸蛋白酶抑制剂)
- 分析运行时间:在2-8℃下过夜(16-18小时)
- 研究类别:代谢
- 研究子类别:代谢紊乱
特點和優勢
聯結
其他說明
法律資訊
訊號詞
Danger
危險分類
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Sens. 1
儲存類別代碼
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
分析證明 (COA)
輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。