推薦產品
agency
meets USP/NF
suitable for ASTM® 7968
suitable for ASTM® 7979
suitable for EPA 1621
suitable for EPA 1633
suitable for EPA 533
suitable for EPA OTM-45
suitable for ISO 21675 2019
suitable for ISO 25101
品質等級
法律遵循
suitable for FDA C-010.02
蒸汽壓力
635 hPa ( 20 °C)
形狀
liquid
expl. lim.
27 %
濃度
28.0-30.0% NH3
雜質
≤0.002% Carbon dioxide (CO2)
≤0.1 ppm Copper (Cu)
≤0.1 ppm Nickel (Ni)
≤0.2 ppm Iron (Fe)
≤0.2 ppm Lead (Pb)
≤0.2 ppm Manganese (Mn)
≤0.3 ppm Aluminum (Al)
≤0.3 ppm Calcium (Ca)
≤0.3 ppm Chromium (Cr)
≤0.3 ppm Gold (Au)
≤0.3 ppm Magnesium (Mg)
≤0.3 ppm Potassium (K)
≤0.3 ppm Sodium (Na)
≤0.3 ppm Tin (Sn)
≤0.3 ppm Titanium (Ti)
≤0.3 ppm Zinc (Zn)
≤0.5 ppm Chloride (Cl)
≤0.5 ppm Heavy metals (as Pb)
≤2 ppm Nitrate (NO3)
≤2 ppm Phosphate (PO4)
≤2 ppm Sulfate (SO4)
燃燒殘留物
≤0.002%
pH值
>12 (20 °C in H2O, strongly alkaline)
bp
32 °C
mp
-72 °C
密度
0.9 g/mL at 25 °C (lit.)
SMILES 字串
[NH4+].[OH-]
運輸包裝
ambient
儲存溫度
room temp
InChI
1S/H3N.H2O/h1H3;1H2
InChI 密鑰
VHUUQVKOLVNVRT-UHFFFAOYSA-N
尋找類似的產品? 前往 產品比較指南
應用
AX1303P-5, AX1303-57 and AX1303-75 are packaged in poly coated glass bottles
分析報告
Appearance: Passes test
Assay (as NH3): 28.0-30.0%
Calcium (Ca): 0.3ppm max
Carbon dioxide (CO2): 0.002% max
Chloride (Cl): 0.5ppm max
Chromium (Cr): 0.3ppm max
Copper (Cu): 0.1ppm max
Gold (Au): 0.3ppm max
Heavy metals (as Pb): 0.5ppm max
Iron (Fe): 0.2ppm max
Lead (Pb): 0.2ppm max
Magnesium (Mg): 0.3ppm max
Manganese (Mn): 0.2ppm max
Nickel (Ni): 0.1ppm max
Nitrate (NO3): 2ppm max
Phosphate (PO4): 2ppm max
Potassium (K): 0.3ppm max
Residue after ignition: 0.002% max
Sodium (Na): 0.3ppm max
Substances reducing permanganate: To pass test
Sulfate (SO4): 2ppm max
Tin (Sn): 0.3ppm max
Titanium (Ti): 0.3ppm max
Zinc (Zn): 0.3ppm max
法律資訊
訊號詞
Danger
危險聲明
危險分類
Aquatic Acute 1 - Aquatic Chronic 1 - Eye Dam. 1 - Skin Corr. 1 - STOT SE 3
標靶器官
Respiratory system
儲存類別代碼
8B - Non-combustible corrosive hazardous materials
水污染物質分類(WGK)
WGK 2
閃點(°F)
Not applicable
閃點(°C)
Not applicable
分析證明 (COA)
輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。
客戶也查看了
文章
Shown here is the chiral separation of amphetamine enantiomers under MS-compatible conditions on Astec CHIROBIOTIC® V2 after extraction from urine using Supel™-Select SCX SPE 96-well plates. The highest grade mobile phase solvents and additives were used to supply low background interference and low particulate contaminants for robust, trouble-free operation. Cerilliant CRMs provided reliable identification and quantification.
Separation of S(+)-Amphetamine (dextro-Amphetamine) solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material; R(-)-Amphetamine (levo-Amphetamine), 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material
條款
LC/MS Analysis of Methamphetamine Enantiomers on Astec® CHIROBIOTIC® V2 in Urine after SPE using Supel™-Select SCX
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務