推薦產品
product name
EXtrelut® NT, packing material for the production of large extraction columns
品質等級
技術
supported liquid extraction (SLE): suitable
pH值
10 (20 °C, 100 g/L in H2O)
mp
>450 °C
溶解度
0.0037 g/L
密度
2.36 g/cm3 at 20 °C
體積密度
300 kg/m3
儲存溫度
15-25°C
InChI
1S/C4H9.Li/c1-3-4-2;/h1,3-4H2,2H3;
InChI 密鑰
MZRVEZGGRBJDDB-UHFFFAOYSA-N
一般說明
應用
- Heart failure biomarkers BNP and NT-proBNP detection using optical labels.: This research utilizes EXtrelut NT for the extraction and analysis of heart failure biomarkers BNP and NT-proBNP. The study highlights the role of EXtrelut NT in enhancing the sensitivity and accuracy of biomarker detection using optical labels, which is critical for the early diagnosis and monitoring of heart failure (Goryacheva et al., 2022).
- Evaluation of the Analytical Performance of BNP and NT-proBNP Assays on the Atellica CI 1900 Analyzer.: This study employs EXtrelut NT to streamline the extraction of BNP and NT-proBNP biomarkers from human plasma and serum samples. The research demonstrates the efficacy of EXtrelut NT in ensuring precise and reproducible results in high-throughput analytical workflows, validating the performance of the Atellica CI 1900 Analyzer in clinical diagnostics (Rhea-McManus et al., 2023).
- NT-proBNP detection with a one-step magnetic lateral flow channel assay.: This study uses EXtrelut NT to facilitate the extraction and purification of NT-proBNP from whole blood samples. The research highlights the role of EXtrelut NT in achieving high sensitivity and accuracy in NT-proBNP detection using a novel magnetic lateral flow assay, which is crucial for point-of-care diagnostics of heart failure (Strohmaier-Nguyen et al., 2024).
- Sample-to-answer lateral flow assay with integrated plasma separation and NT-proBNP detection.: This research employs EXtrelut NT in the development of a sample-to-answer lateral flow assay for NT-proBNP detection. The study emphasizes the pack′s role in ensuring efficient plasma separation and high-sensitivity detection of NT-proBNP in clinical blood samples, highlighting its application in point-of-care testing (Strohmaier-Nguyen et al., 2024).
分析報告
堆积密度:18.0 - 36.0 g/100ml
碱度(Extrelut-20柱):<0.25mmol/E-20-柱
纯度测试
- 280 nm吸光度:
≤ 0.109
- 250 nm吸光度: ≤ 0.157
- 230 nm吸光度: ≤ 0.300
- GC:污染峰不明显
法律資訊
訊號詞
Danger
危險聲明
危險分類
STOT RE 1 Inhalation
標靶器官
Lungs
儲存類別代碼
6.1D - Non-combustible, acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects
水污染物質分類(WGK)
WGK 1
閃點(°F)
Not applicable
閃點(°C)
Not applicable
分析證明 (COA)
輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。
客戶也查看了
文章
Simplify your liquid-liquid extractions with our emulsion-free supported-liquid extraction (SLE) single step solution.
Simplify your liquid-liquid extractions with our emulsion-free supported-liquid extraction (SLE) single step solution.
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務