跳轉至內容
Merck
全部照片(1)

重要文件

T-046

Supelco

睾酮-D3标准液 CRM 溶液

100 μg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®

同義詞:

睾酮-d3 溶液

登入查看組織和合約定價


About This Item

CAS號碼:
EC號碼:
MDL號碼:
分類程式碼代碼:
41116107
PubChem物質ID:
NACRES:
NA.24

等級

certified reference material

品質等級

形狀

liquid

特點

Snap-N-Spike®/Snap-N-Shoot®

包裝

ampule of 1 mL

製造商/商標名

Cerilliant®

濃度

100 μg/mL in acetonitrile

技術

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

應用

clinical testing

形式

single component solution

儲存溫度

−20°C

SMILES 字串

[H]C1([H])C[C@]2([H])[C@@]3([H])CCC4=CC(=O)CC[C@]4(C)[C@]3([H])CC[C@@]2(C)[C@]1([H])O

InChI

1S/C19H28O2/c1-18-9-7-13(20)11-12(18)3-4-14-15-5-6-17(21)19(15,2)10-8-16(14)18/h11,14-17,21H,3-10H2,1-2H3/t14-,15-,16-,17-,18-,19-/m0/s1/i6D2,17D

InChI 密鑰

MUMGGOZAMZWBJJ-HZRGXLBSSA-N

尋找類似的產品? 前往 產品比較指南

一般說明

一种稳定标记的内标物,用于睾酮检测或同位素稀释法(GC/MS 或 LC/MS),用于运动检测、尿液药物检测或 LC-MS/MS 或 GC/MS 诊断检测。睾酮是一种来自雄激素组的激素,是一种重要的性激素和合成代谢类固醇,用作增强性能的药物。

法律資訊

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

相關產品

產品號碼
描述
訂價

象形圖

FlameExclamation mark

訊號詞

Danger

危險分類

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 2

閃點(°F)

35.6 °F - closed cup

閃點(°C)

2 °C - closed cup


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如果您需要協助,請聯絡 客戶支援

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

文章

LC-MS/MS is a powerful tool that brings numerous benefits to the clinical sample analysis arena. However, due to the complexity of the instrumentation there are some unique challenges that also accompany these benefits. Even following sample extraction and cleanup, matrix effects from the samples can cause interferences or impact ionization efficiency.

LC-MS/MS is a powerful tool that brings numerous benefits to the clinical sample analysis arena. However, due to the complexity of the instrumentation there are some unique challenges that also accompany these benefits. Even following sample extraction and cleanup, matrix effects from the samples can cause interferences or impact ionization efficiency.

Global Trade Item Number

庫存單位GTIN
T-046-1ML4061837330087

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務